Semiautomatic Analysis on Computed Tomography in Locally Advanced or Metastatic Non-Small Cell Lung Cancer: Reproducibility and Prognostic Significance of Unidimensional and 3-dimensional Measurements. Issue 5 (September 2015)
- Record Type:
- Journal Article
- Title:
- Semiautomatic Analysis on Computed Tomography in Locally Advanced or Metastatic Non-Small Cell Lung Cancer: Reproducibility and Prognostic Significance of Unidimensional and 3-dimensional Measurements. Issue 5 (September 2015)
- Main Title:
- Semiautomatic Analysis on Computed Tomography in Locally Advanced or Metastatic Non-Small Cell Lung Cancer
- Authors:
- Colombi, Davide
Manna, Carmelinda
Montermini, Ilaria
Seletti, Valeria
Diciotti, Stefano
Tiseo, Marcello
Fontana, Elisa
De Filippo, Massimo
Silva, Mario
Sverzellati, Nicola - Abstract:
- Abstract : Purpose: The aim of the study was to compare both reproducibility and prognostic value of lesion size measurements obtained manually and semiautomatically on computed tomography in advanced non–small cell lung cancer (NSCLC). Materials and Methods: Manual axial longest diameter, semiautomatic axial longest diameter, and volume of NSCLC lesions were independently analyzed by 4 readers at baseline and after at least 1 cycle of platinum-based chemotherapy. The prognostic value of the proportional change in lesion size between baseline and follow-up CT was evaluated using either RECIST or experimental thresholds derived from the quartiles of the changes as assessed manually or semiautomatically. Results: Semiautomatic axial longest diameter (concordance correlation coefficient [CCC]: 0.980 to 0.987; variation coefficient [VC%]: 6% to 7.3%) and volume (CCC: 0.974 to 0.991; VC%: 5.6% to 9.5%) were more reproducible than manual axial longest diameter (CCC: 0.950 to 0.984; VC%: 6.4% to 11.7%). RECIST categories did not stratify patients with different survival durations. For 3/4 readers, a decrease of ⩽70% in lesion volume was associated with shorter survival (median survival: 11 mo, P <0.05; hazard ratio: 5 to 22.2, P <0.05). Conclusions: In advanced NSCLC, semiautomatic measures were more reproducible than manual diameter, and volumetric measurement may better predict patient survival. Abstract : Supplemental Digital Content is available in the text.
- Is Part Of:
- Journal of thoracic imaging. Volume 30:Issue 5(2015)
- Journal:
- Journal of thoracic imaging
- Issue:
- Volume 30:Issue 5(2015)
- Issue Display:
- Volume 30, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 30
- Issue:
- 5
- Issue Sort Value:
- 2015-0030-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-09
- Subjects:
- non–small cell lung cancer -- tumor volume -- multidetector computed tomography -- reproducibility of findings -- survival
Chest -- Radiography -- Periodicals
Chest -- Diseases -- Diagnosis -- Periodicals
617.540757 - Journal URLs:
- http://journals.lww.com/thoracicimaging/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RTI.0000000000000145 ↗
- Languages:
- English
- ISSNs:
- 0883-5993
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5069.120000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: