Precision and accuracy of diffusion kurtosis estimation and the influence of b‐value selection. (25th August 2017)
- Record Type:
- Journal Article
- Title:
- Precision and accuracy of diffusion kurtosis estimation and the influence of b‐value selection. (25th August 2017)
- Main Title:
- Precision and accuracy of diffusion kurtosis estimation and the influence of b‐value selection
- Authors:
- Chuhutin, Andrey
Hansen, Brian
Jespersen, Sune Nørhøj - Abstract:
- Abstract : Diffusion kurtosis imaging (DKI) is an extension of diffusion tensor imaging that accounts for leading non‐Gaussian diffusion effects. In DKI studies, a wide range of different gradient strengths ( b ‐values) is used, which is known to affect the estimated diffusivity and kurtosis parameters. Hence there is a need to assess the accuracy and precision of the estimated parameters as a function of b ‐value. This work examines the error in the estimation of mean of the kurtosis tensor (MKT) with respect to the ground truth, using simulations based on a biophysical model for both gray (GM) and white (WM) matter. Model parameters are derived from densely sampled experimental data acquired in ex vivo rat brain and in vivo human brain. Additionally, the variability of MKT is studied using the experimental data. Prevalent fitting protocols are implemented and investigated. The results show strong dependence on the maximum b ‐value of both net relative error and standard deviation of error for all of the employed fitting protocols. The choice of b ‐values with minimum MKT estimation error and standard deviation of error was found to depend on the protocol type and the tissue. Protocols that utilize two terms of the cumulant expansion (DKI) were found to achieve minimum error in GM at b ‐values less than 1 ms/μm 2, whereas maximal b ‐values of about 2.5 ms/μm 2 were found to be optimal in WM. Protocols including additional higher order terms of the cumulant expansion wereAbstract : Diffusion kurtosis imaging (DKI) is an extension of diffusion tensor imaging that accounts for leading non‐Gaussian diffusion effects. In DKI studies, a wide range of different gradient strengths ( b ‐values) is used, which is known to affect the estimated diffusivity and kurtosis parameters. Hence there is a need to assess the accuracy and precision of the estimated parameters as a function of b ‐value. This work examines the error in the estimation of mean of the kurtosis tensor (MKT) with respect to the ground truth, using simulations based on a biophysical model for both gray (GM) and white (WM) matter. Model parameters are derived from densely sampled experimental data acquired in ex vivo rat brain and in vivo human brain. Additionally, the variability of MKT is studied using the experimental data. Prevalent fitting protocols are implemented and investigated. The results show strong dependence on the maximum b ‐value of both net relative error and standard deviation of error for all of the employed fitting protocols. The choice of b ‐values with minimum MKT estimation error and standard deviation of error was found to depend on the protocol type and the tissue. Protocols that utilize two terms of the cumulant expansion (DKI) were found to achieve minimum error in GM at b ‐values less than 1 ms/μm 2, whereas maximal b ‐values of about 2.5 ms/μm 2 were found to be optimal in WM. Protocols including additional higher order terms of the cumulant expansion were found to provide higher accuracy for the more commonly used b ‐value regime in GM, but were associated with higher error in WM. Averaged over multiple voxels, a net average error of around 15% for both WM and GM was observed for the optimal b ‐value choice. These results suggest caution when using DKI generated metrics for microstructural modeling and when comparing results obtained using different fitting techniques and b ‐values. Abstract : This study shows that the choice of maximum b ‐value is crucial for the estimation of diffusion kurtosis metrics as it impacts their accuracy and precision. We found that the b ‐values that are normally utilized by DKI studies do not yield best accuracy and precision for all tissues. For the optimal choice of b ‐value there was a net average error of 15% for both white and gray matter, which increases if the b ‐values are sub‐optimal. … (more)
- Is Part Of:
- NMR in biomedicine. Volume 30:Number 11(2017:Nov.)
- Journal:
- NMR in biomedicine
- Issue:
- Volume 30:Number 11(2017:Nov.)
- Issue Display:
- Volume 30, Issue 11 (2017)
- Year:
- 2017
- Volume:
- 30
- Issue:
- 11
- Issue Sort Value:
- 2017-0030-0011-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2017-08-25
- Subjects:
- Diffusion weighted imaging -- diffusion methods -- methods and engineering, Biophysical mechanisms of MR diffusion -- diffusion methods -- methods and engineering, high order diffusion MR methods -- diffusion methods -- methods and engineering
Nuclear magnetic resonance -- Periodicals
Magnetic Resonance Spectroscopy -- Periodicals
574 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/nbm.3777 ↗
- Languages:
- English
- ISSNs:
- 0952-3480
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6113.931000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4779.xml