Mun, Goo‐Hyun - Abstract:
- Abstract: Background: Various methods have been introduced for estimating deep inferior epigastric artery perforator (DIEP) flap volume based on computed tomography or magnetic resonance angiographic images. However, when radiologic images cannot be obtained, estimations are subjective. The purpose of this study was to develop a prediction model for estimating DIEP flap weight using the pinch test. Methods: The pinch test was performed at three paraumbilical sites using a skin‐fold caliper in 107 consecutive patients who underwent DIEP flap breast reconstruction. Multiple linear regression analysis was used to develop a formula to estimate flap weight. Predictor variables included body mass index (BMI, kg/m 2 ), flap height ( H, cm), flap width ( W, cm), and flap thickness (mm) measured by the pinch test at the following three paraumbilical sites: 5 cm right ( R ), left ( L ), and inferior ( I ) of the umbilicus. The model accuracy was tested using leave‐one‐out cross‐validation. Results: A prediction model was developed from the multiple regression analysis ( R 2 = 89.03%, P < .001); flap weight, g = −1308 + 24.57 × BMI + 6.80 × ( R + L )/2 + 7.89 × I + 20.51 × H + 32.55 × W . The formula was implemented in a smartphone application, DIEP‐W version 2.0, for real‐time use. The mean absolute percentage error in the cross‐validation was 12.15%. Conclusions: DIEP flap weight can be estimated by the pinch test with the developed prediction model in an easy,Abstract: Background: Various methods have been introduced for estimating deep inferior epigastric artery perforator (DIEP) flap volume based on computed tomography or magnetic resonance angiographic images. However, when radiologic images cannot be obtained, estimations are subjective. The purpose of this study was to develop a prediction model for estimating DIEP flap weight using the pinch test. Methods: The pinch test was performed at three paraumbilical sites using a skin‐fold caliper in 107 consecutive patients who underwent DIEP flap breast reconstruction. Multiple linear regression analysis was used to develop a formula to estimate flap weight. Predictor variables included body mass index (BMI, kg/m 2 ), flap height ( H, cm), flap width ( W, cm), and flap thickness (mm) measured by the pinch test at the following three paraumbilical sites: 5 cm right ( R ), left ( L ), and inferior ( I ) of the umbilicus. The model accuracy was tested using leave‐one‐out cross‐validation. Results: A prediction model was developed from the multiple regression analysis ( R 2 = 89.03%, P < .001); flap weight, g = −1308 + 24.57 × BMI + 6.80 × ( R + L )/2 + 7.89 × I + 20.51 × H + 32.55 × W . The formula was implemented in a smartphone application, DIEP‐W version 2.0, for real‐time use. The mean absolute percentage error in the cross‐validation was 12.15%. Conclusions: DIEP flap weight can be estimated by the pinch test with the developed prediction model in an easy, cost‐effective, and relatively accurate manner. This method will improve surgical planning and allow surgeons to provide better counselling for patients when radiologic images are not available. … (more)
- Is Part Of:
- Microsurgery. Volume 37:Issue 7(2017)
- Journal:
- Microsurgery
- Issue:
- Volume 37:Issue 7(2017)
- Issue Display:
- Volume 37, Issue 7 (2017)
- Year:
- 2017
- Volume:
- 37
- Issue:
- 7
- Issue Sort Value:
- 2017-0037-0007-0000
- Page Start:
- 786
- Page End:
- 792
- Publication Date:
- 2017-09-12
- Subjects:
- Microsurgery -- Periodicals
617.05 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1098-2752 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/micr.30217 ↗
- Languages:
- English
- ISSNs:
- 0738-1085
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5760.770000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4778.xml