Repair of the musculocutaneous nerve using the vagus nerve as donor by helicoid end‐to‐side technique: an experimental study in rats. Issue 12 (3rd May 2017)
- Record Type:
- Journal Article
- Title:
- Repair of the musculocutaneous nerve using the vagus nerve as donor by helicoid end‐to‐side technique: an experimental study in rats. Issue 12 (3rd May 2017)
- Main Title:
- Repair of the musculocutaneous nerve using the vagus nerve as donor by helicoid end‐to‐side technique: an experimental study in rats
- Authors:
- Yan, Ji‐Geng
Shen, Feng‐Yi
Thayer, Jacob
Yan, Yuhui
LoGiudice, John
Matloub, Hani
Sanger, James
Zhang, Lin‐Ling
Havlik, Robert - Abstract:
- Abstract: Although several donor nerves can be chosen to repair avulsed brachial plexus nerve injury, available nerves are still limited. The purpose of this study is to validate whether the vagus nerve (VN) can be used as a donor. Eighteen Sprague‐Dawley male rats were divided into three groups (n = 6). The right musculocutaneous nerve (McN) was transected with differing subsequent repair. (1) HS‐VN group: a saphenous nerve (SN) graft‐end was helicoidally wrapped round the VN side (epi‐and perineurium was opened) with a 30 ° angle, distal SN end was coapted to the McN with end‐to‐end repair. (2) EE‐PN group: a SN was interpositionally grafted between the transected phrenic nerve (PN) and the McN by end‐to‐end coaptation. (3) Sham control group: McN was transected and not repaired and postoperative vital signs were checked daily. At three months, electrophysiology, tetanic force, wet biceps muscle weight, and histology were evaluated. Every tested mean value in HS‐VN group was significantly greater than the EE‐PN or the sham control groups ( p < 0.05 or p < 0.005). The mean recovery ratio of regenerated nerve fibers was 96% and, in HS‐VN group, the mean recovery ratio of CMAP was 79%. No vital signs changed in any group. There was no statistical difference ( p > 0.5) between the mean VN nerve‐fiber numbers of the segments proximal (2237 ± 134) and distal (2150 ± 156) to the VN graft‐attachment site. Histological analysis revealed no axon injury or intraneural scarring atAbstract: Although several donor nerves can be chosen to repair avulsed brachial plexus nerve injury, available nerves are still limited. The purpose of this study is to validate whether the vagus nerve (VN) can be used as a donor. Eighteen Sprague‐Dawley male rats were divided into three groups (n = 6). The right musculocutaneous nerve (McN) was transected with differing subsequent repair. (1) HS‐VN group: a saphenous nerve (SN) graft‐end was helicoidally wrapped round the VN side (epi‐and perineurium was opened) with a 30 ° angle, distal SN end was coapted to the McN with end‐to‐end repair. (2) EE‐PN group: a SN was interpositionally grafted between the transected phrenic nerve (PN) and the McN by end‐to‐end coaptation. (3) Sham control group: McN was transected and not repaired and postoperative vital signs were checked daily. At three months, electrophysiology, tetanic force, wet biceps muscle weight, and histology were evaluated. Every tested mean value in HS‐VN group was significantly greater than the EE‐PN or the sham control groups ( p < 0.05 or p < 0.005). The mean recovery ratio of regenerated nerve fibers was 96% and, in HS‐VN group, the mean recovery ratio of CMAP was 79%. No vital signs changed in any group. There was no statistical difference ( p > 0.5) between the mean VN nerve‐fiber numbers of the segments proximal (2237 ± 134) and distal (2150 ± 156) to the VN graft‐attachment site. Histological analysis revealed no axon injury or intraneural scarring at any point along the VN. This study demonstrated that VN is a practical and reliable donor nerve for end‐to‐side nerve transfer. © 2017 Wiley Periodicals, Inc. Abstract : Although several donor nerves can be chosen to repair avulsed brachial plexus nerve injury, available nerves are still limited. The purpose of this study is to validate whether vagus nerve (VN) can be used as a donor. Photo of HS‐VN repair . Two arrows indicate a nerve graft (NGF), saphenous nerve was helicoidally wrapped around the vagus nerve (VN). A = Common carotid artery. 36x. Bar = 0.28 mm … (more)
- Is Part Of:
- Journal of neuroscience research. Volume 95:Issue 12(2017)
- Journal:
- Journal of neuroscience research
- Issue:
- Volume 95:Issue 12(2017)
- Issue Display:
- Volume 95, Issue 12 (2017)
- Year:
- 2017
- Volume:
- 95
- Issue:
- 12
- Issue Sort Value:
- 2017-0095-0012-0000
- Page Start:
- 2493
- Page End:
- 2499
- Publication Date:
- 2017-05-03
- Subjects:
- brachial plexus nerve -- helicoid end‐to‐side -- nerve injury -- nerve repair -- phrenic nerve -- vagus nerve -- tetanic force machine -- electronic scale -- Image Pro Plus
Neurobiology -- Periodicals
612 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1097-4547 ↗
http://www3.interscience.wiley.com/cgi-bin/jhome/109668564 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jnr.24074 ↗
- Languages:
- English
- ISSNs:
- 0360-4012
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5022.090000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4776.xml