Abstract ID: 28 Evaluation of silicon and diamond based microdosimetry for boron neutron capture therapy quality assurance. (October 2017)
- Record Type:
- Journal Article
- Title:
- Abstract ID: 28 Evaluation of silicon and diamond based microdosimetry for boron neutron capture therapy quality assurance. (October 2017)
- Main Title:
- Abstract ID: 28 Evaluation of silicon and diamond based microdosimetry for boron neutron capture therapy quality assurance
- Authors:
- Guatelli, Susanna
Vohradsky, James
Davis, Jeremy
Tran, Linh T.
Rosenfeld, Anatoly - Abstract:
- Abstract : The shift from reactor to accelerator based neutron production has created a renewed interested in Boron Neutron Capture Therapy (BNCT). BNCT is reliant upon the favourable uptake of boron 10 by tumour cells along with the interaction with neutrons to produce high LET fragments (He and Li nuclei) that deposit energy locally within the tumour site. As with any radiation based treatment, Quality Assurance (QA) is crucial. This study extends previous work regarding the application of solid state microdosimetry in the field of BNCT by means of a dedicated Monte Carlo simulation[1] . Geant4 was used to model and optimise the design of silicon on insulator and diamond based microdosimeters[2, 3] . Detector optimisation in this context pertains to the geometry and materials (i.e., sensitive volume size and probability of neutron activation) to be used in the fabrication of detectors. The study has shown conclusively that whilst the materials currently used in the fabrication of silicon and diamond based microdosimeters are appropriate, there are changes with respect to the sensitive volume thickness that must be addressed. Lastly, the applicability of previously determined correction factors[4] to match the energy deposition response of charged particles within silicon/diamond to water was evaluated within the context of BNCT. Full results and analysis will be presented.
- Is Part Of:
- Physica medica. Volume 42(2017)Supplement 1
- Journal:
- Physica medica
- Issue:
- Volume 42(2017)Supplement 1
- Issue Display:
- Volume 42, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2017-0042-0001-0000
- Page Start:
- 4
- Page End:
- Publication Date:
- 2017-10
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2017.09.011 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4803.xml