Inferior lead discordance in ventricular arrhythmias: A specific marker for certain arrhythmia locations. (16th August 2017)
- Record Type:
- Journal Article
- Title:
- Inferior lead discordance in ventricular arrhythmias: A specific marker for certain arrhythmia locations. (16th August 2017)
- Main Title:
- Inferior lead discordance in ventricular arrhythmias: A specific marker for certain arrhythmia locations
- Authors:
- Enriquez, Andres
Pathak, Rajeev K.
Santangeli, Pasquale
Liang, Jackson J.
Al Rawahi, Mohammed
Hayashi, Tatsuya
Muser, Daniele
Frankel, David S.
Supple, Gregory
Schaller, Robert
Lin, David
Nazarian, Saman
Zado, Erica
Marchlinski, Francis E.
Garcia, Fermin C. - Abstract:
- Abstract: Background: Most idiopathic ventricular arrhythmias (VAs) originate from the outflow tracts and are characterized by an inferior axis on the 12‐lead ECG. A group of patients will exhibit inferior lead discordance (ILD), demonstrating a positive QRS in lead II with negative QRS in III or the opposite finding. Methods and results: We identified patients undergoing ablation of idiopathic premature ventricular contractions (PVCs) or ventricular tachycardia (VT) between 2013 and 2015. The site of earliest activation was determined using electroanatomic mapping and intracardiac echocardiography. Out of 281 patients, 25 (8.9%) exhibited ILD. In patients with positive/negative discordance (n = 18), the source was mapped to the parahisian region in 14 cases and to the right ventricular (RV) moderator band (MB) or papillary muscles (PMs) in 4, while all those with negative/positive discordance (n = 7) were mapped to the anterolateral PM (ALPM). In the group with positive/negative discordance, a later precordial transition (>V4), wider QRS duration, and the presence of notch in the inferior leads pointed toward a RV MB/PM origin. Complete PVC/VT suppression was achieved in 72%. In 2 patients with parahisian PVCs, ablation was not attempted due to risk of heart block. Conclusions: The presence of ILD is associated with particular anatomical locations, namely, the parahisian region, RV MB/PM, and ALPM. The outcomes of ablation are more modest compared to other idiopathic VAs,Abstract: Background: Most idiopathic ventricular arrhythmias (VAs) originate from the outflow tracts and are characterized by an inferior axis on the 12‐lead ECG. A group of patients will exhibit inferior lead discordance (ILD), demonstrating a positive QRS in lead II with negative QRS in III or the opposite finding. Methods and results: We identified patients undergoing ablation of idiopathic premature ventricular contractions (PVCs) or ventricular tachycardia (VT) between 2013 and 2015. The site of earliest activation was determined using electroanatomic mapping and intracardiac echocardiography. Out of 281 patients, 25 (8.9%) exhibited ILD. In patients with positive/negative discordance (n = 18), the source was mapped to the parahisian region in 14 cases and to the right ventricular (RV) moderator band (MB) or papillary muscles (PMs) in 4, while all those with negative/positive discordance (n = 7) were mapped to the anterolateral PM (ALPM). In the group with positive/negative discordance, a later precordial transition (>V4), wider QRS duration, and the presence of notch in the inferior leads pointed toward a RV MB/PM origin. Complete PVC/VT suppression was achieved in 72%. In 2 patients with parahisian PVCs, ablation was not attempted due to risk of heart block. Conclusions: The presence of ILD is associated with particular anatomical locations, namely, the parahisian region, RV MB/PM, and ALPM. The outcomes of ablation are more modest compared to other idiopathic VAs, reflecting the technical difficulties associated with these anatomical locations, such as the proximity to the conduction system in parahisian VAs or stability issues when ablating the PMs or MB. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 28:Number 10(2017)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 28:Number 10(2017)
- Issue Display:
- Volume 28, Issue 10 (2017)
- Year:
- 2017
- Volume:
- 28
- Issue:
- 10
- Issue Sort Value:
- 2017-0028-0010-0000
- Page Start:
- 1179
- Page End:
- 1186
- Publication Date:
- 2017-08-16
- Subjects:
- activation mapping -- catheter ablation -- electrocardiogram -- inferior lead discordance -- ventricular arrhythmias
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.13287 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4773.xml