Reliability and measurement error of the Osteoarthritis Research Society International (OARSI) recommended performance-based tests of physical function in people with hip and knee osteoarthritis. Issue 11 (November 2017)
- Record Type:
- Journal Article
- Title:
- Reliability and measurement error of the Osteoarthritis Research Society International (OARSI) recommended performance-based tests of physical function in people with hip and knee osteoarthritis. Issue 11 (November 2017)
- Main Title:
- Reliability and measurement error of the Osteoarthritis Research Society International (OARSI) recommended performance-based tests of physical function in people with hip and knee osteoarthritis
- Authors:
- Dobson, F.
Hinman, R.S.
Hall, M.
Marshall, C.J.
Sayer, T.
Anderson, C.
Newcomb, N.
Stratford, P.W.
Bennell, K.L. - Abstract:
- Summary: Objective: To estimate the reliability and measurement error of performance-based tests of physical function recommended by the Osteoarthritis Research Society International (OARSI) in people with hip and/or knee osteoarthritis (OA). Design: Prospective repeated measures between independent raters within a session and within-rater over a week interval. Relative reliability was estimated for 51 people with hip and/or knee OA (mean age 64.5 years, standard deviation (SD) 6.21 years; 47% females; 36 (70%) primary knee OA) on the 30s Chair Stand Test (30sCST), 40m Fast-Paced Walk Test (40mFPWT), 11-Stair Climb Test (11-step SCT), Timed Up and Go (TUG), Six-Minute Walk Test (6MWT), 10m Fast-Paced Walk Test (10mFPWT) and 20s Stair Climb Test (20sSCT) using intra-class correlation coefficients (ICC). Absolute reliability was calculated using standard error of measurement (SEM) and minimal detectable change (MDC). Results: Measurement error was acceptable (SEM < 10%) for all tests. Between-rater reliability was: optimal (ICC > 0.9, lower 1-sided 95% CI > 0.7) for the 40mFPWT, 6MWT and 10mFPWT; sufficient (ICC >0.8, lower 1-sided 95% CI > 0.7) for 30sCST, 20sSCT; unacceptable (lower 1-side 95% CI < 0.7) for 11-step SCT and TUG. Within-rater reliability was optimal for 40mFPWT, and 6MWT; sufficient for 30sCST and 10mFPWT and unacceptable for 11-step SCT, TUG and 20sSCT. Conclusions: The 30sCST, 40mFPWT, 6MWT and 10mFPWT, demonstrated, at minimum, acceptable levels of bothSummary: Objective: To estimate the reliability and measurement error of performance-based tests of physical function recommended by the Osteoarthritis Research Society International (OARSI) in people with hip and/or knee osteoarthritis (OA). Design: Prospective repeated measures between independent raters within a session and within-rater over a week interval. Relative reliability was estimated for 51 people with hip and/or knee OA (mean age 64.5 years, standard deviation (SD) 6.21 years; 47% females; 36 (70%) primary knee OA) on the 30s Chair Stand Test (30sCST), 40m Fast-Paced Walk Test (40mFPWT), 11-Stair Climb Test (11-step SCT), Timed Up and Go (TUG), Six-Minute Walk Test (6MWT), 10m Fast-Paced Walk Test (10mFPWT) and 20s Stair Climb Test (20sSCT) using intra-class correlation coefficients (ICC). Absolute reliability was calculated using standard error of measurement (SEM) and minimal detectable change (MDC). Results: Measurement error was acceptable (SEM < 10%) for all tests. Between-rater reliability was: optimal (ICC > 0.9, lower 1-sided 95% CI > 0.7) for the 40mFPWT, 6MWT and 10mFPWT; sufficient (ICC >0.8, lower 1-sided 95% CI > 0.7) for 30sCST, 20sSCT; unacceptable (lower 1-side 95% CI < 0.7) for 11-step SCT and TUG. Within-rater reliability was optimal for 40mFPWT, and 6MWT; sufficient for 30sCST and 10mFPWT and unacceptable for 11-step SCT, TUG and 20sSCT. Conclusions: The 30sCST, 40mFPWT, 6MWT and 10mFPWT, demonstrated, at minimum, acceptable levels of both between and within-rater reliability and measurement error. All tests demonstrated sufficiently small measurement error indicating they are adequate for measuring change over time in individuals with knee/hip OA. … (more)
- Is Part Of:
- Osteoarthritis and cartilage. Volume 25:Issue 11(2017)
- Journal:
- Osteoarthritis and cartilage
- Issue:
- Volume 25:Issue 11(2017)
- Issue Display:
- Volume 25, Issue 11 (2017)
- Year:
- 2017
- Volume:
- 25
- Issue:
- 11
- Issue Sort Value:
- 2017-0025-0011-0000
- Page Start:
- 1792
- Page End:
- 1796
- Publication Date:
- 2017-11
- Subjects:
- Osteoarthritis -- Performance-based tests -- Physical function -- Outcomes -- Reliability -- Measurement error
Osteoarthritis -- Periodicals
Cartilage -- Periodicals
Osteoarthritis -- Periodicals
Cartilage -- Periodicals
Arthrose -- Périodiques
Articulations -- Maladies -- Périodiques
616.7223005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10634584 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10634584 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.joca.2017.06.006 ↗
- Languages:
- English
- ISSNs:
- 1063-4584
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6303.858870
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4768.xml