Radon barrier: Method of testing airtightness - 2. Edition. (October 2017)
- Record Type:
- Journal Article
- Title:
- Radon barrier: Method of testing airtightness - 2. Edition. (October 2017)
- Main Title:
- Radon barrier: Method of testing airtightness - 2. Edition
- Authors:
- Rasmussen, Torben Valdbjørn
Cornelius, Thomas - Abstract:
- Abstract: The test method NBI 167/02 Radon membrane: Test of airtightness can be used for determining the airtightness of a radon barrier as a system solution. The test determines the air infiltration through the radon barrier for a number of levels of air pressure differences. The airflow through versus the difference in air pressure over the barrier is measured. The air pressure difference is kept constant, at a number of manually controlled levels. At each pressure level, the difference is measured in a single point close to the point where the suction for lowering the air pressure is located. Improvements to the test method were suggested. A digital stirring and control system, and a method for determining the mean air pressure difference, as well as a method for testing barriers with a very low air infiltration, were provided. The digital stirring and control system ensured automatic control and measuring of coherent values of the airflow and the difference in air pressure. The method determining the mean air pressure difference was based on measurements from 5 units placed at specific locations. The method for testing barriers with a very low air infiltration introduced the need to provide air to the side of the barrier with the low air pressure, through a well-defined opening, as a modification of the test method in general. Results, obtained using the improved test method, are shown for a number of radon barriers tested.
- Is Part Of:
- Energy procedia. Volume 132(2017)
- Journal:
- Energy procedia
- Issue:
- Volume 132(2017)
- Issue Display:
- Volume 132, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 132
- Issue:
- 2017
- Issue Sort Value:
- 2017-0132-2017-0000
- Page Start:
- 819
- Page End:
- 824
- Publication Date:
- 2017-10
- Subjects:
- Radon Barrier -- Airtightness -- Test Method
Power resources -- Congresses
Power resources -- Periodicals
Power resources
Conference proceedings
Periodicals
333.7905 - Journal URLs:
- http://www.sciencedirect.com/science/journal/18766102 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.egypro.2017.10.017 ↗
- Languages:
- English
- ISSNs:
- 1876-6102
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3747.729700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4799.xml