Long term monitoring of repaired external wall assembly. (October 2017)
- Record Type:
- Journal Article
- Title:
- Long term monitoring of repaired external wall assembly. (October 2017)
- Main Title:
- Long term monitoring of repaired external wall assembly
- Authors:
- Ahola, Susanna
Lahdensivu, Jukka - Abstract:
- Abstract: This study discusses on hygrothermal performance of external wall assembly based on long term observation on relative humidity and temperature in layered external wall assembly, when the resistance of water vapor in insulating material is higher than in the main framing of the studied building. In this case the location of the vapor barrier must be examined more closely. In 1974 completed building the facade of the building was made from concrete and bricks. The external wall assembly was repaired by replacing the thermal insulation and facade brickwork. The original brick-insulation-brick structure was unventilated like those used to be until mid-1980s. The repaired outer layer was constructed with a ventilation gap which satisfies the building codes in force. Old thermal insulation was replaced with aluminum foil backed polyurethane insulation. The aim of the study was to verify that the new structure was performing properly by measuring the circumstances inside the new external wall assembly. The performance of the repaired external wall was monitored by sensors installed in four depths and in five different locations in the building. Each of the sensors measured relative humidity and temperature for two years. The repaired external wall assembly was observed to be performing correctly. The aluminum foil backed polyurethane insulation functioned as planned as wall assembly's thermal insulation and vapor barrier. Condensation of the indoor air into the structureAbstract: This study discusses on hygrothermal performance of external wall assembly based on long term observation on relative humidity and temperature in layered external wall assembly, when the resistance of water vapor in insulating material is higher than in the main framing of the studied building. In this case the location of the vapor barrier must be examined more closely. In 1974 completed building the facade of the building was made from concrete and bricks. The external wall assembly was repaired by replacing the thermal insulation and facade brickwork. The original brick-insulation-brick structure was unventilated like those used to be until mid-1980s. The repaired outer layer was constructed with a ventilation gap which satisfies the building codes in force. Old thermal insulation was replaced with aluminum foil backed polyurethane insulation. The aim of the study was to verify that the new structure was performing properly by measuring the circumstances inside the new external wall assembly. The performance of the repaired external wall was monitored by sensors installed in four depths and in five different locations in the building. Each of the sensors measured relative humidity and temperature for two years. The repaired external wall assembly was observed to be performing correctly. The aluminum foil backed polyurethane insulation functioned as planned as wall assembly's thermal insulation and vapor barrier. Condensation of the indoor air into the structure was not detected during the measurement period. Neither was the outside air's relative humidity condensed outside the vapor barrier during the measurement period. There was no observation of the condensation neither in the ventilation gap, nor in the fire resistant mineral wool layer during the measurement period, in any inside or outside circumstances. … (more)
- Is Part Of:
- Energy procedia. Volume 132(2017)
- Journal:
- Energy procedia
- Issue:
- Volume 132(2017)
- Issue Display:
- Volume 132, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 132
- Issue:
- 2017
- Issue Sort Value:
- 2017-0132-2017-0000
- Page Start:
- 375
- Page End:
- 380
- Publication Date:
- 2017-10
- Subjects:
- Brick-insulation-brick structure -- monitoring -- relative humidity -- condensation -- diffusion
Power resources -- Congresses
Power resources -- Periodicals
Power resources
Conference proceedings
Periodicals
333.7905 - Journal URLs:
- http://www.sciencedirect.com/science/journal/18766102 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.egypro.2017.09.635 ↗
- Languages:
- English
- ISSNs:
- 1876-6102
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3747.729700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4798.xml