Evaluation of the accuracy of extraoral laboratory scanners with a single-tooth abutment model: A 3D analysis. Issue 4 (December 2017)
- Record Type:
- Journal Article
- Title:
- Evaluation of the accuracy of extraoral laboratory scanners with a single-tooth abutment model: A 3D analysis. Issue 4 (December 2017)
- Main Title:
- Evaluation of the accuracy of extraoral laboratory scanners with a single-tooth abutment model: A 3D analysis
- Authors:
- Mandelli, Federico
Gherlone, Enrico
Gastaldi, Giorgio
Ferrari, Marco - Abstract:
- Abstract: Purpose: The aim of this study was to compare the accuracy of different laboratory scanners using a calibrated coordinate measuring machine as reference. Methods: A sand blasted titanium reference model (RM) was scanned with an industrial 3D scanner in order to obtain a reference digital model (dRM) that was saved in the standard tessellation format (.stl). RM was scanned ten times with each one of the tested scanners (GC Europe Aadva, Zfx Evolution, 3Shape D640, 3Shape D700, NobilMetal Sinergia, EGS DScan3, Open Technologies Concept Scan Top) and all the scans were exported in .stl format for the comparison. All files were imported in a dedicated software (Geomagic Qualify 2013). Accuracy was evaluated calculating trueness and precision. Results: Trueness values (μm [95% confidence interval]) were: Aadva 7, 7 [6, 8–8, 5]; Zfx Evolution 9, 2 [8, 6–9, 8]; D640 18, 1 [12, 2–24, 0]; D700 12, 8 [12, 4–13, 3]; Sinergia 31, 1 [26, 3–35, 9]; DScan3 15, 6 [11, 5–19, 7]; Concept Scan Top 28, 6 [25, 6–31, 6]. Differences between scanners were statistically significant (p < .0005). Precision values (μm [95% CI]) were: Aadva 4, 0 [3, 8–4, 2]; Zfx Evolution 5, 1 [4, 4–5, 9]; D640 12, 7 [12, 4–13, 1]; D700 11, 0 [10, 7–11, 3]; Sinergia 16, 3 [15, 0–17, 5]; DScan3 9, 5 [8, 3–10, 6]; Concept Scan Top 19, 5 [19, 1–19, 8]. Differences between scanners were statistically significant (p < .0005). Conclusions: The use a standardized scanning procedure fabricating a titanium referenceAbstract: Purpose: The aim of this study was to compare the accuracy of different laboratory scanners using a calibrated coordinate measuring machine as reference. Methods: A sand blasted titanium reference model (RM) was scanned with an industrial 3D scanner in order to obtain a reference digital model (dRM) that was saved in the standard tessellation format (.stl). RM was scanned ten times with each one of the tested scanners (GC Europe Aadva, Zfx Evolution, 3Shape D640, 3Shape D700, NobilMetal Sinergia, EGS DScan3, Open Technologies Concept Scan Top) and all the scans were exported in .stl format for the comparison. All files were imported in a dedicated software (Geomagic Qualify 2013). Accuracy was evaluated calculating trueness and precision. Results: Trueness values (μm [95% confidence interval]) were: Aadva 7, 7 [6, 8–8, 5]; Zfx Evolution 9, 2 [8, 6–9, 8]; D640 18, 1 [12, 2–24, 0]; D700 12, 8 [12, 4–13, 3]; Sinergia 31, 1 [26, 3–35, 9]; DScan3 15, 6 [11, 5–19, 7]; Concept Scan Top 28, 6 [25, 6–31, 6]. Differences between scanners were statistically significant (p < .0005). Precision values (μm [95% CI]) were: Aadva 4, 0 [3, 8–4, 2]; Zfx Evolution 5, 1 [4, 4–5, 9]; D640 12, 7 [12, 4–13, 1]; D700 11, 0 [10, 7–11, 3]; Sinergia 16, 3 [15, 0–17, 5]; DScan3 9, 5 [8, 3–10, 6]; Concept Scan Top 19, 5 [19, 1–19, 8]. Differences between scanners were statistically significant (p < .0005). Conclusions: The use a standardized scanning procedure fabricating a titanium reference model is useful to compare trueness and precision of different laboratory scanners; two laboratory scanners (Aadva, Zfx Evolution) were significantly better that other tested scanners. … (more)
- Is Part Of:
- Journal of prosthodontic research. Volume 61:Issue 4(2017)
- Journal:
- Journal of prosthodontic research
- Issue:
- Volume 61:Issue 4(2017)
- Issue Display:
- Volume 61, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 61
- Issue:
- 4
- Issue Sort Value:
- 2017-0061-0004-0000
- Page Start:
- 363
- Page End:
- 370
- Publication Date:
- 2017-12
- Subjects:
- Extraoral digital impression -- Extraoral scanning -- Repeatability -- Precision
Prosthodontics -- Periodicals
Dentistry -- Periodicals
Prosthodontics -- Periodicals
Electronic journals
Computer network resources
617.6905 - Journal URLs:
- http://www.sciencedirect.com/science/journal/18831958 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jpor.2016.09.002 ↗
- Languages:
- English
- ISSNs:
- 1883-1958
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5042.915000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4778.xml