Influence of different image‐guided tracking methods upon the local efficacy of CyberKnife treatment in lung tumors. Issue 3 (May 2015)
- Record Type:
- Journal Article
- Title:
- Influence of different image‐guided tracking methods upon the local efficacy of CyberKnife treatment in lung tumors. Issue 3 (May 2015)
- Main Title:
- Influence of different image‐guided tracking methods upon the local efficacy of CyberKnife treatment in lung tumors
- Authors:
- Guo, Yihang
Zhuang, Hongqing
Zhao, Lujun
Yuan, Zhiyong
Wang, Ping - Abstract:
- Abstract: Background: The aim of this study was to explore the influence of image‐guided tumor localization modality (Synchrony tracking vs. Xsight spine‐based localization) on the local efficacy of CyberKnife treatment in lung cancer and lung metastases. Methods: Retrospective analysis of 64 patients with pulmonary metastases and primary tumor cases (72 targets) treated with stereotactic body radiotherapy using CyberKnife was conducted. Synchrony respiratory tracking was used to treat 45 targets, and the remaining 27 targets were treated using Xsight spine (with an extended margin to account for positional uncertainty). The median (80%) isodose line (70–94%) covered the planning target volume at a total dose of 6000 cGy delivered in three fractions. Local efficacy was evaluated by Response Evaluation Criteria in Solid Tumors, accompanied by the follow‐up of local recurrence cases and analysis of tracking methods. Results: Short‐term local control was superior for targets tracked with Synchrony than for targets localized with Xsight spine. There was no statistical difference for targets in the upper lung, but for targets in the lower lung Synchrony tracking was better. Small targets (less than 15 mL) were better controlled when Synchrony was used, but there was no difference for treatment volumes larger than 15 mL. Treatment failures were more likely in the lower lung and for small tumors localized with Xsight spine. Conclusions: The local efficacy of CyberKnife treatment inAbstract: Background: The aim of this study was to explore the influence of image‐guided tumor localization modality (Synchrony tracking vs. Xsight spine‐based localization) on the local efficacy of CyberKnife treatment in lung cancer and lung metastases. Methods: Retrospective analysis of 64 patients with pulmonary metastases and primary tumor cases (72 targets) treated with stereotactic body radiotherapy using CyberKnife was conducted. Synchrony respiratory tracking was used to treat 45 targets, and the remaining 27 targets were treated using Xsight spine (with an extended margin to account for positional uncertainty). The median (80%) isodose line (70–94%) covered the planning target volume at a total dose of 6000 cGy delivered in three fractions. Local efficacy was evaluated by Response Evaluation Criteria in Solid Tumors, accompanied by the follow‐up of local recurrence cases and analysis of tracking methods. Results: Short‐term local control was superior for targets tracked with Synchrony than for targets localized with Xsight spine. There was no statistical difference for targets in the upper lung, but for targets in the lower lung Synchrony tracking was better. Small targets (less than 15 mL) were better controlled when Synchrony was used, but there was no difference for treatment volumes larger than 15 mL. Treatment failures were more likely in the lower lung and for small tumors localized with Xsight spine. Conclusions: The local efficacy of CyberKnife treatment in lung cancer and lung metastases was influenced by image‐guided localization method, target location within the lung, and tumor volume. … (more)
- Is Part Of:
- Thoracic cancer. Volume 6:Issue 3(2015)
- Journal:
- Thoracic cancer
- Issue:
- Volume 6:Issue 3(2015)
- Issue Display:
- Volume 6, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 6
- Issue:
- 3
- Issue Sort Value:
- 2015-0006-0003-0000
- Page Start:
- 255
- Page End:
- 259
- Publication Date:
- 2015-05
- Subjects:
- CyberKnife -- lung tumor -- real‐time image‐ guided tracking -- Synchrony -- Xsight spine
Chest -- Cancer -- Periodicals
Chest -- Cancer -- Treatment -- Periodicals
Chest -- Surgery -- Periodicals
616.99494005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/%28ISSN%291759-7714;jsessionid=9202029487E02D838DF722140677202D.d04t01 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1759-7714 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.wiley.com/bw/journal.asp?ref=1759-7706&site=1 ↗ - DOI:
- 10.1111/1759-7714.12174 ↗
- Languages:
- English
- ISSNs:
- 1759-7706
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8820.242500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4764.xml