New embedding and staining systems PrestoCHILL and Presto stainer for application in the advancement of Mohs micrographic surgery. Issue 4 (2nd October 2017)
- Record Type:
- Journal Article
- Title:
- New embedding and staining systems PrestoCHILL and Presto stainer for application in the advancement of Mohs micrographic surgery. Issue 4 (2nd October 2017)
- Main Title:
- New embedding and staining systems PrestoCHILL and Presto stainer for application in the advancement of Mohs micrographic surgery
- Authors:
- Orchard, GE
Shams, M
d'Amico, C
Wojcik, K
Ismail, F
Mohammad, M
Salih, R
Shams, F
Mallipeddi, R - Abstract:
- Abstract: Background: Mohs micrographic surgery (MMS) involves evaluation of frozen tissue sections to determine complete circumferential and deep tissue margin clearance of skin tumours. PrestoCHILL and Presto stainer devices are two new innovative tools which bring benefits of automation, speed and efficiency to the preparation of frozen section analysis in MMS. The devices were assessed at Viapath's Tissue Science Mohs laboratory at Guy's Cancer Centre. Material and Methods: A total of 279 samples from 10 anatomically different facial sites. These included nose (95), lip (24), forehead (47), cheek (25), eyelids (34), temple (9), chin (15), ear (17), scalp (6) and neck (7). These were analysed using both devices simultaneously. Results: The PrestoCHILL device was measured for accuracy of tissue orientation by determining how many of the cases examined microscopically had complete margin and full epidermis preservation. The precision and reproducibility of the Presto stainer was evaluated by the consistency of achieving ideal standards of staining quality as defined by the department's internal quality control check, on stained sections examined and evaluated microscopically. The mean (standard deviation) score for accuracy for the PrestoCHILL across all tissue facial sites was 93.5 (11)%; the mean (standard deviation) score for precision/reproducibility of the Presto stainer was 96.5 (11)% (both p < 0.05). Conclusion: The devices combined offer an assured accuracy andAbstract: Background: Mohs micrographic surgery (MMS) involves evaluation of frozen tissue sections to determine complete circumferential and deep tissue margin clearance of skin tumours. PrestoCHILL and Presto stainer devices are two new innovative tools which bring benefits of automation, speed and efficiency to the preparation of frozen section analysis in MMS. The devices were assessed at Viapath's Tissue Science Mohs laboratory at Guy's Cancer Centre. Material and Methods: A total of 279 samples from 10 anatomically different facial sites. These included nose (95), lip (24), forehead (47), cheek (25), eyelids (34), temple (9), chin (15), ear (17), scalp (6) and neck (7). These were analysed using both devices simultaneously. Results: The PrestoCHILL device was measured for accuracy of tissue orientation by determining how many of the cases examined microscopically had complete margin and full epidermis preservation. The precision and reproducibility of the Presto stainer was evaluated by the consistency of achieving ideal standards of staining quality as defined by the department's internal quality control check, on stained sections examined and evaluated microscopically. The mean (standard deviation) score for accuracy for the PrestoCHILL across all tissue facial sites was 93.5 (11)%; the mean (standard deviation) score for precision/reproducibility of the Presto stainer was 96.5 (11)% (both p < 0.05). Conclusion: The devices combined offer an assured accuracy and precision performance, which is reproducible across all facial tissue types examined. The devices represent a key step forward in the introduction of improved automated embedding and staining procedures within MMS. … (more)
- Is Part Of:
- British journal of biomedical science. Volume 74:Issue 4(2017)
- Journal:
- British journal of biomedical science
- Issue:
- Volume 74:Issue 4(2017)
- Issue Display:
- Volume 74, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 74
- Issue:
- 4
- Issue Sort Value:
- 2017-0074-0004-0000
- Page Start:
- 203
- Page End:
- 208
- Publication Date:
- 2017-10-02
- Subjects:
- Mohs -- PrestoCHILL -- Presto stainer -- frozen sections
Medical sciences -- Periodicals
Medical technology -- Periodicals
Biological Science Disciplines
Clinical Laboratory Techniques
Medical Laboratory Science
Anatomie pathologique
Medical sciences
Medical technology
Klinische chemie
Laboratoriumonderzoek
Periodicals
Periodicals
616.0756
610.07 M489L - Journal URLs:
- http://catalog.hathitrust.org/api/volumes/oclc/27845663.html ↗
http://www.ibms.org/index.cfm?method=publications.british_journal ↗
http://www.tandfonline.com/loi/tbbs20?open=67&repitition=0 ↗
https://www.frontierspartnerships.org/journals/british-journal-of-biomedical-science ↗ - DOI:
- 10.1080/09674845.2017.1348566 ↗
- Languages:
- English
- ISSNs:
- 0967-4845
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2306.730000
British Library HMNTS - ELD Digital store - Ingest File:
- 4762.xml