A dual-label time-resolved fluorescence immunoassay for the simultaneous determination of cystatin C and β2-microglobulin in urine. Issue 4 (2nd October 2017)
- Record Type:
- Journal Article
- Title:
- A dual-label time-resolved fluorescence immunoassay for the simultaneous determination of cystatin C and β2-microglobulin in urine. Issue 4 (2nd October 2017)
- Main Title:
- A dual-label time-resolved fluorescence immunoassay for the simultaneous determination of cystatin C and β2-microglobulin in urine
- Authors:
- Liu, Y
Liu, YH
Bei, WJ
Wang, K
Cui, TT
Li, HL
Wu, DX
Chen, SQ
Tan, N
Chen, JY - Abstract:
- Abstract: Background : Contrast media is widely used in clinical diagnostic and interventional procedures, but may cause damage to the kidney, that is, contrast-induced nephropathy. This study was to establish a dual-label time-resolved fluorescence immunoassay (TRFIA) for the simultaneous determination of renal function markers cystatin-C (Cys-C) and β2 -microglobulin (β2 -MG) for the early diagnosis and follow-up surveillance of contrast-induced nephropathy. Methods : A sandwich immunoassay was used to detect the concentration of Cys-C, and the competitive immunoassay was used to detect the concentration of β2 -MG in 50 samples of urine. The performance of this dual-label TRFIA was evaluated and compared with commercial assays. Results : The sensitivity for Cys-C detection was 1.26 ng/ml, the average recovery was 99.36%; The sensitivity for β2 -MG detection was 2.13 ng/ml, the average recovery was 100.18%. Bland–Altman analysis showed that the dual-label TRFIA method and the commercial kits had a good agreement, suggesting they can be used interchangeably in clinical urine analysis. Conclusion : The present dual-label TRFIA has high sensitivity, specificity and accuracy in clinical sample analysis. This method can be used for the early diagnosis and follow-up surveillance of the contrast-induced nephropathy.
- Is Part Of:
- British journal of biomedical science. Volume 74:Issue 4(2017)
- Journal:
- British journal of biomedical science
- Issue:
- Volume 74:Issue 4(2017)
- Issue Display:
- Volume 74, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 74
- Issue:
- 4
- Issue Sort Value:
- 2017-0074-0004-0000
- Page Start:
- 193
- Page End:
- 197
- Publication Date:
- 2017-10-02
- Subjects:
- Contrast-induced nephropathy -- cystatin-C -- β2-microglobulin -- dual-label time-resolved fluorescence immunoassay
Medical sciences -- Periodicals
Medical technology -- Periodicals
Biological Science Disciplines
Clinical Laboratory Techniques
Medical Laboratory Science
Anatomie pathologique
Medical sciences
Medical technology
Klinische chemie
Laboratoriumonderzoek
Periodicals
Periodicals
616.0756
610.07 M489L - Journal URLs:
- http://catalog.hathitrust.org/api/volumes/oclc/27845663.html ↗
http://www.ibms.org/index.cfm?method=publications.british_journal ↗
http://www.tandfonline.com/loi/tbbs20?open=67&repitition=0 ↗
https://www.frontierspartnerships.org/journals/british-journal-of-biomedical-science ↗ - DOI:
- 10.1080/09674845.2017.1334740 ↗
- Languages:
- English
- ISSNs:
- 0967-4845
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2306.730000
British Library HMNTS - ELD Digital store - Ingest File:
- 4762.xml