The thermoluminescence glow curve and the deconvoluted glow peak characteristics of erbium doped silica fiber exposed to 70–130 kVp x-rays. (October 2015)
- Record Type:
- Journal Article
- Title:
- The thermoluminescence glow curve and the deconvoluted glow peak characteristics of erbium doped silica fiber exposed to 70–130 kVp x-rays. (October 2015)
- Main Title:
- The thermoluminescence glow curve and the deconvoluted glow peak characteristics of erbium doped silica fiber exposed to 70–130 kVp x-rays
- Authors:
- Alawiah, A.
Bauk, S.
Marashdeh, M.W.
Nazura, M.Z.N.
Abdul-Rashid, H.A.
Yusoff, Z.
Gieszczyk, W.
Noramaliza, M.N.
Mahamd Adikan, F.R.
Mahdiraji, G.A.
Tamchek, N.
Muhd-Yassin, S.Z.
Mat-Sharif, K.A.
Zulkifli, M.I.
Omar, N.
Wan Abdullah, W.S.
Bradley, D.A. - Abstract:
- Abstract: In regard to thermoluminescence (TL) applied to dosimetry, in recent times a number of researchers have explored the role of optical fibers for radiation detection and measurement. Many of the studies have focused on the specific dopant concentration, the type of dopant and the fiber core diameter, all key dependencies in producing significant increase in the sensitivity of such fibers. At doses of less than 1 Gy none of these investigations have addressed the relationship between dose response and TL glow peak behavior of erbium (Er)-doped silica cylindrical fibers (CF). For x-rays obtained at accelerating potentials from 70 to 130 kVp, delivering doses of between 0.1 and 0.7 Gy, present study explores the issue of dose response, special attention being paid to determination of the kinetic parameters and dosimetric peak properties of Er-doped CF. The effect of dose response on the kinetic parameters of the glow peak has been compared against other fiber types, revealing previously misunderstood connections between kinetic parameters and radiation dose. Within the investigated dose range there was an absence of supralinearity of response of the Er-doped silica CF, instead sub-linear response being observed. Detailed examination of glow peak response and kinetic parameters has thus been shown to shed new light of the rarely acknowledged issue of the limitation of TL kinetic model and sub-linear dose response of Er-doped silica CF. Highlights: Supralinearity was notAbstract: In regard to thermoluminescence (TL) applied to dosimetry, in recent times a number of researchers have explored the role of optical fibers for radiation detection and measurement. Many of the studies have focused on the specific dopant concentration, the type of dopant and the fiber core diameter, all key dependencies in producing significant increase in the sensitivity of such fibers. At doses of less than 1 Gy none of these investigations have addressed the relationship between dose response and TL glow peak behavior of erbium (Er)-doped silica cylindrical fibers (CF). For x-rays obtained at accelerating potentials from 70 to 130 kVp, delivering doses of between 0.1 and 0.7 Gy, present study explores the issue of dose response, special attention being paid to determination of the kinetic parameters and dosimetric peak properties of Er-doped CF. The effect of dose response on the kinetic parameters of the glow peak has been compared against other fiber types, revealing previously misunderstood connections between kinetic parameters and radiation dose. Within the investigated dose range there was an absence of supralinearity of response of the Er-doped silica CF, instead sub-linear response being observed. Detailed examination of glow peak response and kinetic parameters has thus been shown to shed new light of the rarely acknowledged issue of the limitation of TL kinetic model and sub-linear dose response of Er-doped silica CF. Highlights: Supralinearity was not observed within the dose range of 0.1–0.7 Gy. Er doped silica CF showed a sub-linear response. The peak height and T max showed a significant dependency on dose. The kinetics parameters were highly dependence on dose. … (more)
- Is Part Of:
- Applied radiation and isotopes. Volume 104(2015:Oct.)
- Journal:
- Applied radiation and isotopes
- Issue:
- Volume 104(2015:Oct.)
- Issue Display:
- Volume 104 (2015)
- Year:
- 2015
- Volume:
- 104
- Issue Sort Value:
- 2015-0104-0000-0000
- Page Start:
- 197
- Page End:
- 202
- Publication Date:
- 2015-10
- Subjects:
- Sub-linearity -- TL kinetic model -- Kinetic parameters -- Glow curve -- Glow peak
Radiology -- Periodicals
Radiation -- Industrial applications -- Periodicals
Nuclear chemistry -- Periodicals
Internet resource
Periodical
660.298 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09698043 ↗
http://catalog.hathitrust.org/api/volumes/oclc/27456684.html ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apradiso.2015.07.011 ↗
- Languages:
- English
- ISSNs:
- 0969-8043
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1576.565000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4753.xml