Effect of various upper limb multibody models on soft tissue artefact correction: A case study. (6th September 2017)
- Record Type:
- Journal Article
- Title:
- Effect of various upper limb multibody models on soft tissue artefact correction: A case study. (6th September 2017)
- Main Title:
- Effect of various upper limb multibody models on soft tissue artefact correction: A case study
- Authors:
- Naaim, Alexandre
Moissenet, Florent
Duprey, Sonia
Begon, Mickaël
Chèze, Laurence - Abstract:
- Abstract: Soft tissue artefacts (STA) introduce errors in joint kinematics when using cutaneous markers, especially on the scapula. Both segmental optimisation and multibody kinematics optimisation (MKO) algorithms have been developed to improve kinematics estimates. MKO based on a chain model with joint constraints avoids apparent joint dislocation but is sensitive to the biofidelity of chosen joint constraints. Since no recommendation exists for the scapula, our objective was to determine the best models to accurately estimate its kinematics. One participant was equipped with skin markers and with an intracortical pin screwed in the scapula. Segmental optimisation and MKO for 24-chain models (including four variations of the scapulothoracic joint) were compared against the pin-derived kinematics using root mean square error (RMSE) on Cardan angles. Segmental optimisation led to an accurate scapula kinematics (1.1° ≤ RMSE ≤ 3.3°) even for high arm elevation angles. When MKO was applied, no clinically significant difference was found between the different scapulothoracic models (0.9° ≤ RMSE ≤ 4.1°) except when a free scapulothoracic joint was modelled (1.9° ≤ RMSE ≤ 9.6°). To conclude, using MKO as a STA correction method was not more accurate than segmental optimisation for estimating scapula kinematics.
- Is Part Of:
- Journal of biomechanics. Volume 62(2017)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 62(2017)
- Issue Display:
- Volume 62, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 62
- Issue:
- 2017
- Issue Sort Value:
- 2017-0062-2017-0000
- Page Start:
- 102
- Page End:
- 109
- Publication Date:
- 2017-09-06
- Subjects:
- Soft tissue artefact -- Multibody kinematics optimisation -- Upper limb -- Shoulder -- Kinematics model
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2017.01.031 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4753.xml