A biomechanical study comparing proximal femur nail and proximal femur locking compression plate in fixation of reverse oblique proximal femur fractures. Issue 10 (October 2017)
- Record Type:
- Journal Article
- Title:
- A biomechanical study comparing proximal femur nail and proximal femur locking compression plate in fixation of reverse oblique proximal femur fractures. Issue 10 (October 2017)
- Main Title:
- A biomechanical study comparing proximal femur nail and proximal femur locking compression plate in fixation of reverse oblique proximal femur fractures
- Authors:
- Singh, Ashutosh Kumar
Narsaria, N.
Gupta, R.K. - Abstract:
- Abstract: Background: The reverse oblique trochanteric fractures are common fractures and its treatment poses a challenge. The purpose of this study was to compare the biomechanical parameters of the construct using proximal femoral nail (PFN) and proximal femoral locking compression plates (PFLCP) in these fractures using cadaveric specimens. Materials and Methods: Twenty freshly harvested cadaveric femoral specimens were randomly assigned to two groups after measuring bone mineral density, ten of which were implanted with PFN and the other ten with PFLCP. The constructs were made unstable to simulate reverse oblique trochanteric fracture (AO type 31A3.3) by removing a standard size posteromedial wedge. These constructs were tested in a computer controlled cyclic compressive loading with 200 kg at a frequency of 1 cycle/s (1 Hz) and test was observed for 50, 000 cycles or until implant failure, whichever occurred earlier. Peak displacements were measured and analysis was done to determine axial stiffness and subsidence in axial loading. Results: All the specimens in PFN group completed 50, 000 cycles and in PFLCP group, seven specimens completed 50, 000 cycles. Average subsidence in PFN group was 1.24 ± 0.22 mm and in PFLCP group was 1.48 ± 0.38 mm. The average stiffness of PFN group (72.6 ± 6.8 N/mm) was significantly higher than of PFLCP group (62.4 ± 4.9 N/mm) (P = 0.04). The average number of cycles sustained by PFLCP was 46634 and for PFN group was 50, 000 (P = 0.06).Abstract: Background: The reverse oblique trochanteric fractures are common fractures and its treatment poses a challenge. The purpose of this study was to compare the biomechanical parameters of the construct using proximal femoral nail (PFN) and proximal femoral locking compression plates (PFLCP) in these fractures using cadaveric specimens. Materials and Methods: Twenty freshly harvested cadaveric femoral specimens were randomly assigned to two groups after measuring bone mineral density, ten of which were implanted with PFN and the other ten with PFLCP. The constructs were made unstable to simulate reverse oblique trochanteric fracture (AO type 31A3.3) by removing a standard size posteromedial wedge. These constructs were tested in a computer controlled cyclic compressive loading with 200 kg at a frequency of 1 cycle/s (1 Hz) and test was observed for 50, 000 cycles or until implant failure, whichever occurred earlier. Peak displacements were measured and analysis was done to determine axial stiffness and subsidence in axial loading. Results: All the specimens in PFN group completed 50, 000 cycles and in PFLCP group, seven specimens completed 50, 000 cycles. Average subsidence in PFN group was 1.24 ± 0.22 mm and in PFLCP group was 1.48 ± 0.38 mm. The average stiffness of PFN group (72.6 ± 6.8 N/mm) was significantly higher than of PFLCP group (62.4 ± 4.9 N/mm) (P = 0.04). The average number of cycles sustained by PFLCP was 46634 and for PFN group was 50, 000 (P = 0.06). Conclusion: The PFN is biomechanically superior to PFLCP in terms of axial stiffness, subsidence and number of specimens failed for the fixation of reverse oblique trochanteric fractures of femur. … (more)
- Is Part Of:
- Injury. Volume 48:Issue 10(2017)
- Journal:
- Injury
- Issue:
- Volume 48:Issue 10(2017)
- Issue Display:
- Volume 48, Issue 10 (2017)
- Year:
- 2017
- Volume:
- 48
- Issue:
- 10
- Issue Sort Value:
- 2017-0048-0010-0000
- Page Start:
- 2050
- Page End:
- 2053
- Publication Date:
- 2017-10
- Subjects:
- Reverse oblique -- Trochanteric fractures -- Proximal femoral nail -- Proximal femoral locking compression plates -- Unstable -- Dual energy X-ray absorptiometry -- Gap-osteotomy
Wounds and injuries -- Surgery -- Periodicals
Accidents -- Periodicals
Wounds and Injuries -- surgery -- Periodicals
Lésions et blessures -- Chirurgie -- Périodiques
Electronic journals
Electronic journals
617.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00201383 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00201383 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00201383 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.injury.2017.05.029 ↗
- Languages:
- English
- ISSNs:
- 0020-1383
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4514.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4745.xml