Humeral head circle‐fit method greatly increases reliability and accuracy when measuring anterior–posterior radiographs of the proximal humerus. Issue 10 (10th February 2017)
- Record Type:
- Journal Article
- Title:
- Humeral head circle‐fit method greatly increases reliability and accuracy when measuring anterior–posterior radiographs of the proximal humerus. Issue 10 (10th February 2017)
- Main Title:
- Humeral head circle‐fit method greatly increases reliability and accuracy when measuring anterior–posterior radiographs of the proximal humerus
- Authors:
- Mears, Chad S.
Langston, Tanner D.
Phippen, Colton M.
Burkhead, Wayne Z.
Skedros, John G. - Abstract:
- ABSTRACT: Measurements made on routine A–P radiographs can predict strength/quality of the proximal humerus, as shown in terms of two easy‐to‐measure parameters: Cortical index (CI) and mean‐combined cortical thickness (MCCT). Because of high variability inherent when using established methods to measure these parameters, we describe a new orientation system. Using digitized radiographs of 33 adult proximal humeri, five observers measured anatomical reference locations in accordance with: (i) Tingart et al. (2003) method, (ii) Mather et al. (2013) method, and (iii) our new humeral head Circle‐Fit method (CFM). The Tingart and Mather methods measure CI and MCCT with respect to upper and lower edges of 20 mm tall rectangles fit to a proximal diaphyseal location where endosteal (Tingart) or periosteal (Mather) cortical margins become parallel. But high intra‐ and inter‐observer variability occurs when placing the rectangles because of uncertainty in identifying cortical parallelism. With the CFM an adjustable circle is fit to the humeral head articular surface, which reliably and easily establishes a proximal metaphyseal landmark (M1) at the surgical neck. Distal locations are then designated at successive 10 mm increments below M1, including a second metaphyseal landmark (M2) followed by diaphyseal (D) locations (D1, D2 ⋯D6). D1 corresponds most closely to the proximal edges of the rectangles used in the other methods. Results showed minimal inter‐observer variations (meanABSTRACT: Measurements made on routine A–P radiographs can predict strength/quality of the proximal humerus, as shown in terms of two easy‐to‐measure parameters: Cortical index (CI) and mean‐combined cortical thickness (MCCT). Because of high variability inherent when using established methods to measure these parameters, we describe a new orientation system. Using digitized radiographs of 33 adult proximal humeri, five observers measured anatomical reference locations in accordance with: (i) Tingart et al. (2003) method, (ii) Mather et al. (2013) method, and (iii) our new humeral head Circle‐Fit method (CFM). The Tingart and Mather methods measure CI and MCCT with respect to upper and lower edges of 20 mm tall rectangles fit to a proximal diaphyseal location where endosteal (Tingart) or periosteal (Mather) cortical margins become parallel. But high intra‐ and inter‐observer variability occurs when placing the rectangles because of uncertainty in identifying cortical parallelism. With the CFM an adjustable circle is fit to the humeral head articular surface, which reliably and easily establishes a proximal metaphyseal landmark (M1) at the surgical neck. Distal locations are then designated at successive 10 mm increments below M1, including a second metaphyseal landmark (M2) followed by diaphyseal (D) locations (D1, D2 ⋯D6). D1 corresponds most closely to the proximal edges of the rectangles used in the other methods. Results showed minimal inter‐observer variations (mean error, 1.5 ± 1.1 mm) when the CFM is used to establish diaphyseal locations for making CI and MCCT measurements when compared to each of the other methods (mean error range, 10.7 ± 5.9 to 13.3 ± 6.7 mm) ( p < 0.001). © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2313–2322, 2017. … (more)
- Is Part Of:
- Journal of orthopaedic research. Volume 35:Issue 10(2017)
- Journal:
- Journal of orthopaedic research
- Issue:
- Volume 35:Issue 10(2017)
- Issue Display:
- Volume 35, Issue 10 (2017)
- Year:
- 2017
- Volume:
- 35
- Issue:
- 10
- Issue Sort Value:
- 2017-0035-0010-0000
- Page Start:
- 2313
- Page End:
- 2322
- Publication Date:
- 2017-02-10
- Subjects:
- humerus -- radiograph -- cortical index -- circle‐fit method -- reliability -- cortical thickness
Orthopedics -- Periodicals
Musculoskeletal system -- Periodicals
616.7 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jor.23520 ↗
- Languages:
- English
- ISSNs:
- 0736-0266
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.665000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4737.xml