Aortic 4D flow: Quantification of signal‐to‐noise ratio as a function of field strength and contrast enhancement for 1.5T, 3T, and 7T. Issue 5 (16th June 2014)
- Record Type:
- Journal Article
- Title:
- Aortic 4D flow: Quantification of signal‐to‐noise ratio as a function of field strength and contrast enhancement for 1.5T, 3T, and 7T. Issue 5 (16th June 2014)
- Main Title:
- Aortic 4D flow: Quantification of signal‐to‐noise ratio as a function of field strength and contrast enhancement for 1.5T, 3T, and 7T
- Authors:
- Hess, Aaron T.
Bissell, Malenka M.
Ntusi, Ntobeko A.B.
Lewis, Andrew J.M.
Tunnicliffe, Elizabeth M.
Greiser, Andreas
Stalder, Aurelien F.
Francis, Jane M.
Myerson, Saul G.
Neubauer, Stefan
Robson, Matthew D. - Abstract:
- Abstract : Purpose: To investigate for the first time the feasibility of aortic four‐dimensional (4D) flow at 7T, both contrast enhanced (CE) and non‐CE. To quantify the signal‐to‐noise ratio (SNR) in aortic 4D flow as a function of field strength and CE with gadobenate dimeglumine (MultiHance). Methods: Six healthy male volunteers were scanned at 1.5T, 3T, and 7T with both non‐CE and CE acquisitions. Temporal SNR was calculated. Flip angle optimization for CE 4D flow was carried out using Bloch simulations that were validated against in vivo measurements. Results: The 7T provided 2.2 times the SNR of 3T while 3T provided 1.7 times the SNR of 1.5T in non‐CE acquisitions in the descending aorta. The SNR gains achieved by CE were 1.8‐fold at 1.5T, 1.7‐fold at 3T, and 1.4‐fold at 7T, respectively. Conclusion: The 7T provides a new tool to explore aortic 4D flow, yielding higher SNR that can be used to push the boundaries of acceleration and resolution. Field strength and contrast enhancement at all fields provide significant improvements in SNR. Magn Reson Med 73:1864–1871, 2015. © 2014 Wiley Periodicals, Inc.
- Is Part Of:
- Magnetic resonance in medicine. Volume 73:Issue 5(2015:May)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 73:Issue 5(2015:May)
- Issue Display:
- Volume 73, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 73
- Issue:
- 5
- Issue Sort Value:
- 2015-0073-0005-0000
- Page Start:
- 1864
- Page End:
- 1871
- Publication Date:
- 2014-06-16
- Subjects:
- 4D flow -- ultrahigh field -- 7t -- aorta -- blood flow
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25317 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4737.xml