Homologous black‐bright‐blood and flexible interleaved imaging sequence (HOBBI) for dynamic contrast‐enhanced MRI of the vessel wall. Issue 5 (7th May 2014)
- Record Type:
- Journal Article
- Title:
- Homologous black‐bright‐blood and flexible interleaved imaging sequence (HOBBI) for dynamic contrast‐enhanced MRI of the vessel wall. Issue 5 (7th May 2014)
- Main Title:
- Homologous black‐bright‐blood and flexible interleaved imaging sequence (HOBBI) for dynamic contrast‐enhanced MRI of the vessel wall
- Authors:
- Wu, Tingting
Wang, Jinnan
Song, Yan
Deng, Xiaotao
Li, Anqi
Wei, Juan
He, Le
Zhao, Xihai
Li, Rui
Zhou, Zechen
Wu, Wenchuan
Huang, Juan
Jiao, Sheng
Yuan, Chun
Chen, Huijun - Abstract:
- Abstract : Purpose: To present a HOmologous Black‐Bright‐blood and flexible Interleaved imaging (HOBBI) sequence for dynamic contrast‐enhanced magnetic resonance imaging (MRI) of the vessel wall. Theory and Methods: A HOBBI sequence is proposed to acquire high‐spatial‐resolution black‐blood and high‐temporal‐resolution bright‐blood dynamic contrast‐enhanced images in an interleaved fashion. Black‐blood imaging allows for thin vessel wall evaluation, whereas bright‐blood imaging obtains the arterial input function accurately. A simulation was performed to assess the accuracy of the pharmacokinetic parameters [transfer constant ( K trans ) and fractional plasma volume ( v p )] generated from HOBBI. In vivo evaluation was also used to validate HOBBI in an animal model of aortic atherosclerosis. Results: In the simulation test, the estimated K trans and v p measured by HOBBI were more accurate than those from black‐blood dynamic contrast‐enhanced‐MRI. In the animal model testing, K trans and v p also demonstrated good interscan reproducibility ( K trans : ICC = 0.77, v p : ICC = 0.72, respectively). Additionally, K trans showed a significant increase from 1 month (0.026 ± 0.013 min −1 ) to 2 months (0.069 ± 0.018 min −1 ) in animal model plaque progression after balloon injury. Conclusion: The proposed HOBBI sequence was demonstrated to be feasible and accurate in estimating the pharmacokinetic parameters of the atherosclerotic vessel wall, and has potential to become an earlyAbstract : Purpose: To present a HOmologous Black‐Bright‐blood and flexible Interleaved imaging (HOBBI) sequence for dynamic contrast‐enhanced magnetic resonance imaging (MRI) of the vessel wall. Theory and Methods: A HOBBI sequence is proposed to acquire high‐spatial‐resolution black‐blood and high‐temporal‐resolution bright‐blood dynamic contrast‐enhanced images in an interleaved fashion. Black‐blood imaging allows for thin vessel wall evaluation, whereas bright‐blood imaging obtains the arterial input function accurately. A simulation was performed to assess the accuracy of the pharmacokinetic parameters [transfer constant ( K trans ) and fractional plasma volume ( v p )] generated from HOBBI. In vivo evaluation was also used to validate HOBBI in an animal model of aortic atherosclerosis. Results: In the simulation test, the estimated K trans and v p measured by HOBBI were more accurate than those from black‐blood dynamic contrast‐enhanced‐MRI. In the animal model testing, K trans and v p also demonstrated good interscan reproducibility ( K trans : ICC = 0.77, v p : ICC = 0.72, respectively). Additionally, K trans showed a significant increase from 1 month (0.026 ± 0.013 min −1 ) to 2 months (0.069 ± 0.018 min −1 ) in animal model plaque progression after balloon injury. Conclusion: The proposed HOBBI sequence was demonstrated to be feasible and accurate in estimating the pharmacokinetic parameters of the atherosclerotic vessel wall, and has potential to become an early screening tool for atherosclerosis disease. Magn Reson Med 73:1754–1763, 2015. © 2014 Wiley Periodicals, Inc. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 73:Issue 5(2015:May)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 73:Issue 5(2015:May)
- Issue Display:
- Volume 73, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 73
- Issue:
- 5
- Issue Sort Value:
- 2015-0073-0005-0000
- Page Start:
- 1754
- Page End:
- 1763
- Publication Date:
- 2014-05-07
- Subjects:
- dynamic contrast‐enhanced‐magnetic resonance imaging -- atherosclerosis -- sequence
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25287 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4737.xml