Rapid and highly sensitive detection of extracellular and intracellular H2S by an azide-functionalized Al(iii)-based metal–organic framework. Issue 38 (18th September 2017)
- Record Type:
- Journal Article
- Title:
- Rapid and highly sensitive detection of extracellular and intracellular H2S by an azide-functionalized Al(iii)-based metal–organic framework. Issue 38 (18th September 2017)
- Main Title:
- Rapid and highly sensitive detection of extracellular and intracellular H2S by an azide-functionalized Al(iii)-based metal–organic framework
- Authors:
- Nandi, Soutick
Reinsch, Helge
Banesh, Sooram
Stock, Norbert
Trivedi, Vishal
Biswas, Shyam - Abstract:
- Abstract : Fast and highly sensitive sensing of both extracellular and intracellular H2 S by an Al(iii )-based CAU-10-N3 MOF is presented. Abstract : A new, azide-functionalized Al(iii )-based metal–organic framework (MOF) denoted as CAU-10-N3 (1, CAU = Christian-Albrechts-University) and consisting of the 5-azido-isophthalic acid (H2 IPA-N3 ) ligand was employed as a reaction-based fluorescent turn-on probe for the detection of H2 S. The activated compound (1′ ) showed fast, selective and highly sensitive sensing properties for extracellular H2 S in HEPES buffer (10 mM, pH = 7.4). The material retained its high selectivity even in the presence of possibly competing biological species. The limit of detection of1′ for H2 S is 2.65 μM, which is lower than the earlier reports on MOFs for H2 S sensing. The material displayed a short response time (420 s) and a significant increase (20-fold and 26-fold after 1 and 7 min of addition of Na2 S, respectively) in the fluorescence intensity towards H2 S. Macrophage cells loaded with probe1′ exhibited blue fluorescence with a response time of 15 min after Na2 S addition, indicating the suitability of the probe for intracellular H2 S detection. Moreover, CAU-10-N3 featured excellent detection performance (quick response and 32-fold increment in fluorescence intensity after 7 min of Na2 S addition) in water. Hence, it can be utilized to regulate the H2 S level in aqueous samples collected from the environment.
- Is Part Of:
- Dalton transactions. Volume 46:Issue 38(2017)
- Journal:
- Dalton transactions
- Issue:
- Volume 46:Issue 38(2017)
- Issue Display:
- Volume 46, Issue 38 (2017)
- Year:
- 2017
- Volume:
- 46
- Issue:
- 38
- Issue Sort Value:
- 2017-0046-0038-0000
- Page Start:
- 12856
- Page End:
- 12864
- Publication Date:
- 2017-09-18
- Subjects:
- Chemistry, Inorganic -- Periodicals
Chemistry, Physical and theoretical -- Periodicals
Chemistry, Inorganic -- Periodicals
546.05 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/dt#!issueid=dt043040&type=current&issnprint=1477-9226 ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c7dt02293j ↗
- Languages:
- English
- ISSNs:
- 1477-9226
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3517.830000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4721.xml