The application of a blunt‐tip needle to suture the dorsal venous complex in robot‐assisted laparoscopic radical prostatectomy. Issue 3 (31st March 2017)
- Record Type:
- Journal Article
- Title:
- The application of a blunt‐tip needle to suture the dorsal venous complex in robot‐assisted laparoscopic radical prostatectomy. Issue 3 (31st March 2017)
- Main Title:
- The application of a blunt‐tip needle to suture the dorsal venous complex in robot‐assisted laparoscopic radical prostatectomy
- Authors:
- Zhang, Chao
Wang, Huiqing
Ye, Chen
Guo, Fei
Yang, Bo
Xu, Chuanliang
Sun, Yinghao - Abstract:
- Abstract: Objectives: Complete haemostasis of the dorsal venous complex (DVC) is of great importance in robot‐assisted radical prostatectomy. In this study, we investigated the efficacy of blunt‐tip needles in the surgery. Methods: Cases of robot‐assisted laparoscopic radical prostatectomy were reviewed. If a blunt‐tip needle had been used to suture the DVC, the patient was recruited to the blunt‐tip group. If a regular needle was used, the patient was recruited to the control group. Patient characteristics and perioperative outcomes were recorded. Results: One hundred and nine cases were reviewed. A blunt‐tip needle was used to suture the DVC in 67 cases, and a regular needle in 42 cases. All characteristics of the two groups are comparable ( p > 0.05). In 66 cases in the blunt‐tip group, no sutures or coagulations were needed when suturing the DVC, Five cases of DVC‐related bleeding were observed in the control group, which is higher than in the blunt‐tip group ( p = 0.031). At the same time, no catheter was sutured in the blunt‐tip group. All patients were followed for at least six months. The continence rate in the blunt‐tip group is 89.6%, significantly higher than in the control group (73.8%, p = 0.031). Conclusions: Using a blunt‐tip needle to suture the DVC may reduce DVC‐related bleeding and provide a better surgical field. It may be helpful in improving postoperative continence. However, its effect on positive margin at the apex still needs further investigation.
- Is Part Of:
- International journal of medical robotics and computer assisted surgery. Volume 13:Issue 3(2017)
- Journal:
- International journal of medical robotics and computer assisted surgery
- Issue:
- Volume 13:Issue 3(2017)
- Issue Display:
- Volume 13, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 13
- Issue:
- 3
- Issue Sort Value:
- 2017-0013-0003-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2017-03-31
- Subjects:
- blunt‐tip needle -- dorsal vein complex -- haemostasis -- radical prostatectomy -- robot‐assisted laparoscopic surgery
Robotics in medicine -- Periodicals
Surgery -- Technological innovations -- Periodicals
Imaging systems in medicine -- Periodicals
617.90285 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1478-596X ↗
http://www.roboticpublications.com ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/rcs.1822 ↗
- Languages:
- English
- ISSNs:
- 1478-5951
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.347800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4712.xml