Changes in blood volume indicators and dynamic indicators measured with transpulmonary ultrasound velocity during blood depletion and repletion in a neonatal swine model. Issue 11 (13th October 2017)
- Record Type:
- Journal Article
- Title:
- Changes in blood volume indicators and dynamic indicators measured with transpulmonary ultrasound velocity during blood depletion and repletion in a neonatal swine model. Issue 11 (13th October 2017)
- Main Title:
- Changes in blood volume indicators and dynamic indicators measured with transpulmonary ultrasound velocity during blood depletion and repletion in a neonatal swine model
- Authors:
- Martin‐Flores, Manuel
Cisternas, Alvaro F.
Gleed, Robin D. - Editors:
- Vutskits, Laszlo
- Abstract:
- Summary: Background: Dynamic indicators such as pulse pressure and stroke volume variations can be measured to track changes in preload during hemorrhage, and evaluate fluid therapy. However, these dynamic indicators require mechanical ventilation, and might be affected by cardiac dysrhythmias and changes in vascular tone. Blood volume indicators may offer alternatives for assessing changes in volume status. Aims: The aims of this study were to measure changes in blood volume indicators and dynamic indicators during removal of blood in two stages and subsequent blood replacement in anesthetized, mechanically ventilated, neonatal pigs. Methods: In eight anesthetized, mechanically ventilated piglets (5‐6 weeks old), cardiac index, stroke volume index, total end‐diastolic volume, central blood volume, active circulating volume, pulse pressure variation, and stroke volume variation were measured during blood removal in two stages (15 mL kg −1 each stage) and blood replacement (30 mL kg −1 ). Values after each intervention were measured for each parameter. Results: All indicators differed from baseline after removal of 15 mL kg −1 of blood, except for stroke volume variation. Differences between both stages of hemorrhage were only observed for indexed stroke volume, total end‐diastolic volume, central blood volume, and pulse pressure variation. Conclusion: Total end‐diastolic volume and central blood volume changed during blood depletion and repletion, and differed between stagesSummary: Background: Dynamic indicators such as pulse pressure and stroke volume variations can be measured to track changes in preload during hemorrhage, and evaluate fluid therapy. However, these dynamic indicators require mechanical ventilation, and might be affected by cardiac dysrhythmias and changes in vascular tone. Blood volume indicators may offer alternatives for assessing changes in volume status. Aims: The aims of this study were to measure changes in blood volume indicators and dynamic indicators during removal of blood in two stages and subsequent blood replacement in anesthetized, mechanically ventilated, neonatal pigs. Methods: In eight anesthetized, mechanically ventilated piglets (5‐6 weeks old), cardiac index, stroke volume index, total end‐diastolic volume, central blood volume, active circulating volume, pulse pressure variation, and stroke volume variation were measured during blood removal in two stages (15 mL kg −1 each stage) and blood replacement (30 mL kg −1 ). Values after each intervention were measured for each parameter. Results: All indicators differed from baseline after removal of 15 mL kg −1 of blood, except for stroke volume variation. Differences between both stages of hemorrhage were only observed for indexed stroke volume, total end‐diastolic volume, central blood volume, and pulse pressure variation. Conclusion: Total end‐diastolic volume and central blood volume changed during blood depletion and repletion, and differed between stages of hemorrhage. These indicators might be useful for assessing volume status instead of, or in addition to cardiac index and dynamic indicators. … (more)
- Is Part Of:
- Paediatric anaesthesia. Volume 27:Issue 11(2017:Nov.)
- Journal:
- Paediatric anaesthesia
- Issue:
- Volume 27:Issue 11(2017:Nov.)
- Issue Display:
- Volume 27, Issue 11 (2017)
- Year:
- 2017
- Volume:
- 27
- Issue:
- 11
- Issue Sort Value:
- 2017-0027-0011-0000
- Page Start:
- 1136
- Page End:
- 1141
- Publication Date:
- 2017-10-13
- Subjects:
- blood volume -- cardiac output -- hemorrhage -- stroke volume
Pediatric anesthesia -- Periodicals
617.96798 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1155-5645&site=1 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1460-9592 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/pan.13232 ↗
- Languages:
- English
- ISSNs:
- 1155-5645
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6333.399705
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4711.xml