Adaptive bulk motion exclusion for improved robustness of abdominal magnetic resonance imaging. (8th September 2017)
- Record Type:
- Journal Article
- Title:
- Adaptive bulk motion exclusion for improved robustness of abdominal magnetic resonance imaging. (8th September 2017)
- Main Title:
- Adaptive bulk motion exclusion for improved robustness of abdominal magnetic resonance imaging
- Authors:
- Stemkens, Bjorn
Benkert, Thomas
Chandarana, Hersh
Bittman, Mark E.
Van den Berg, Cornelis A.T.
Lagendijk, Jan J.W.
Sodickson, Daniel K.
Tijssen, Rob H.N.
Block, Kai Tobias - Abstract:
- Abstract : Non‐Cartesian magnetic resonance imaging (MRI) sequences have shown great promise for abdominal examination during free breathing, but break down in the presence of bulk patient motion (i.e. voluntary or involuntary patient movement resulting in translation, rotation or elastic deformations of the body). This work describes a data‐consistency‐driven image stabilization technique that detects and excludes bulk movements during data acquisition. Bulk motion is identified from changes in the signal intensity distribution across different elements of a multi‐channel receive coil array. A short free induction decay signal is acquired after excitation and used as a measure to determine alterations in the load distribution. The technique has been implemented on a clinical MR scanner and evaluated in the abdomen. Six volunteers were scanned and two radiologists scored the reconstructions. To show the applicability to other body areas, additional neck and knee images were acquired. Data corrupted by bulk motion were successfully detected and excluded from image reconstruction. An overall increase in image sharpness and reduction of streaking and shine‐through artifacts were seen in the volunteer study, as well as in the neck and knee scans. The proposed technique enables automatic real‐time detection and exclusion of bulk motion during MR examinations without user interaction. It may help to improve the reliability of pediatric MRI examinations without the use of sedation.Abstract : Non‐Cartesian magnetic resonance imaging (MRI) sequences have shown great promise for abdominal examination during free breathing, but break down in the presence of bulk patient motion (i.e. voluntary or involuntary patient movement resulting in translation, rotation or elastic deformations of the body). This work describes a data‐consistency‐driven image stabilization technique that detects and excludes bulk movements during data acquisition. Bulk motion is identified from changes in the signal intensity distribution across different elements of a multi‐channel receive coil array. A short free induction decay signal is acquired after excitation and used as a measure to determine alterations in the load distribution. The technique has been implemented on a clinical MR scanner and evaluated in the abdomen. Six volunteers were scanned and two radiologists scored the reconstructions. To show the applicability to other body areas, additional neck and knee images were acquired. Data corrupted by bulk motion were successfully detected and excluded from image reconstruction. An overall increase in image sharpness and reduction of streaking and shine‐through artifacts were seen in the volunteer study, as well as in the neck and knee scans. The proposed technique enables automatic real‐time detection and exclusion of bulk motion during MR examinations without user interaction. It may help to improve the reliability of pediatric MRI examinations without the use of sedation. Abstract : A data consistency‐driven image stabilization technique is described that automatically detects and excludes bulk patient movements during data acquisition. Bulk motion is identified from changes in the signal intensity distribution across different elements of a multi‐channel receive coil, using a short free induction decay signal. The proposed technique leads to an overall improvement of image quality and sharpness, and to a reduction in visible artifacts. … (more)
- Is Part Of:
- NMR in biomedicine. Volume 30:Number 11(2017:Nov.)
- Journal:
- NMR in biomedicine
- Issue:
- Volume 30:Number 11(2017:Nov.)
- Issue Display:
- Volume 30, Issue 11 (2017)
- Year:
- 2017
- Volume:
- 30
- Issue:
- 11
- Issue Sort Value:
- 2017-0030-0011-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2017-09-08
- Subjects:
- abdominal imaging -- bulk motion -- motion correction -- prospective motion detection -- real‐time motion detection
Nuclear magnetic resonance -- Periodicals
Magnetic Resonance Spectroscopy -- Periodicals
574 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/nbm.3830 ↗
- Languages:
- English
- ISSNs:
- 0952-3480
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6113.931000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4703.xml