Respiratory motion artifacts during arterial phase imaging with gadoxetic acid: Can the injection protocol minimize this drawback?. Issue 4 (9th February 2017)
- Record Type:
- Journal Article
- Title:
- Respiratory motion artifacts during arterial phase imaging with gadoxetic acid: Can the injection protocol minimize this drawback?. Issue 4 (9th February 2017)
- Main Title:
- Respiratory motion artifacts during arterial phase imaging with gadoxetic acid: Can the injection protocol minimize this drawback?
- Authors:
- Polanec, Stephan H.
Bickel, Hubert
Baltzer, Pascal A.T.
Thurner, Patrick
Gittler, Florian
Hodge, Jacqueline C.
Bashir, Mustafa R.
Ba‐Ssalamah, Ahmed - Abstract:
- Abstract : Purpose: To determine which of three gadoxetic acid injection techniques best reduced the contrast‐related arterial‐phase motion artifacts. Materials and Methods: This Institutional Review Board (IRB)‐approved, retrospective study included a cohort of 78 consecutive patients who each had serial gadoxetic acid‐enhanced 3.0T magnetic resonance imaging (MRI) of the liver (0.025 mmol/kg body weight) performed with at least two of three injection techniques: M1 test bolus, undiluted, power‐injected 1 mL/s; M2 test bolus, diluted 50% with saline, power‐injected 1 mL/s; M3 fixed delay, undiluted, manually injected. Blinded to the injection method, three readers independently rated the randomized images for arterial‐phase motion artifacts, arterial‐phase timing, and arterial‐phase lesion visibility using a four‐point Likert scale. Results: Regarding respiratory artifacts, gadoxetic acid arterial‐phase images were judged better with M3 (2.7 ± 0.7) and were significantly less than those with M1 (2.1 ± 1.1) ( P = 0.0001). Arterial‐phase M2 (2.50 ± 0.89) images were rated significantly better than arterial‐phase M1 images ( P = 0.012), but the difference between arterial‐phase images with M3 and M2 scores was not statistically significant ( P = 0.49). Arterial‐phase timing was significantly better for M1 compared to M3, and for M2 compared to M3 ( P < 0.0001 for both). The area under the curve was 0.59–0.68. However, there was no significant difference between M1 and M2 (Abstract : Purpose: To determine which of three gadoxetic acid injection techniques best reduced the contrast‐related arterial‐phase motion artifacts. Materials and Methods: This Institutional Review Board (IRB)‐approved, retrospective study included a cohort of 78 consecutive patients who each had serial gadoxetic acid‐enhanced 3.0T magnetic resonance imaging (MRI) of the liver (0.025 mmol/kg body weight) performed with at least two of three injection techniques: M1 test bolus, undiluted, power‐injected 1 mL/s; M2 test bolus, diluted 50% with saline, power‐injected 1 mL/s; M3 fixed delay, undiluted, manually injected. Blinded to the injection method, three readers independently rated the randomized images for arterial‐phase motion artifacts, arterial‐phase timing, and arterial‐phase lesion visibility using a four‐point Likert scale. Results: Regarding respiratory artifacts, gadoxetic acid arterial‐phase images were judged better with M3 (2.7 ± 0.7) and were significantly less than those with M1 (2.1 ± 1.1) ( P = 0.0001). Arterial‐phase M2 (2.50 ± 0.89) images were rated significantly better than arterial‐phase M1 images ( P = 0.012), but the difference between arterial‐phase images with M3 and M2 scores was not statistically significant ( P = 0.49). Arterial‐phase timing was significantly better for M1 compared to M3, and for M2 compared to M3 ( P < 0.0001 for both). The area under the curve was 0.59–0.68. However, there was no significant difference between M1 and M2 ( P = 0.35). With regard to arterial‐phase lesion visibility, there was no significant difference in the ratings between any of the three injection techniques ( P = 0.29–0.72). Interreader agreement was moderate to substantial (κ = 0.41–0.62). Conclusion: A diluted, power‐injected protocol (M2) seems to provide good timing and minimize artifacts compared with two other injection methods. No significant difference was found in lesion visibility between these three methods. Level of Evidence: 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1107–1114. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 46:Issue 4(2017)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 46:Issue 4(2017)
- Issue Display:
- Volume 46, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 46
- Issue:
- 4
- Issue Sort Value:
- 2017-0046-0004-0000
- Page Start:
- 1107
- Page End:
- 1114
- Publication Date:
- 2017-02-09
- Subjects:
- liver -- MRI -- gadoxetic acid -- artifacts -- contrast‐related artifacts -- transient severe motion artifacts
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25657 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4687.xml