Topologically preserving straightening of spinal cord MRI. Issue 4 (27th January 2017)
- Record Type:
- Journal Article
- Title:
- Topologically preserving straightening of spinal cord MRI. Issue 4 (27th January 2017)
- Main Title:
- Topologically preserving straightening of spinal cord MRI
- Authors:
- De Leener, Benjamin
Mangeat, Gabriel
Dupont, Sara
Martin, Allan R.
Callot, Virginie
Stikov, Nikola
Fehlings, Michael G.
Cohen‐Adad, Julien - Abstract:
- Abstract : Purpose: To propose a robust and accurate method for straightening magnetic resonance (MR) images of the spinal cord, based on spinal cord segmentation, that preserves spinal cord topology and that works for any MRI contrast, in a context of spinal cord template‐based analysis. Materials and Methods: The spinal cord curvature was computed using an iterative Non‐Uniform Rational B‐Spline (NURBS) approximation. Forward and inverse deformation fields for straightening were computed by solving analytically the straightening equations for each image voxel. Computational speed‐up was accomplished by solving all voxel equation systems as one single system. Straightening accuracy (mean and maximum distance from straight line), computational time, and robustness to spinal cord length was evaluated using the proposed and the standard straightening method (label‐based spline deformation) on 3T T 2 ‐ and T 1 ‐weighted images from 57 healthy subjects and 33 patients with spinal cord compression due to degenerative cervical myelopathy (DCM). Results: The proposed algorithm was more accurate, more robust, and faster than the standard method (mean distance = 0.80 vs. 0.83 mm, maximum distance = 1.49 vs. 1.78 mm, time = 71 vs. 174 sec for the healthy population and mean distance = 0.65 vs. 0.68 mm, maximum distance = 1.28 vs. 1.55 mm, time = 32 vs. 60 sec for the DCM population). Conclusion: A novel image straightening method that enables template‐based analysis of quantitativeAbstract : Purpose: To propose a robust and accurate method for straightening magnetic resonance (MR) images of the spinal cord, based on spinal cord segmentation, that preserves spinal cord topology and that works for any MRI contrast, in a context of spinal cord template‐based analysis. Materials and Methods: The spinal cord curvature was computed using an iterative Non‐Uniform Rational B‐Spline (NURBS) approximation. Forward and inverse deformation fields for straightening were computed by solving analytically the straightening equations for each image voxel. Computational speed‐up was accomplished by solving all voxel equation systems as one single system. Straightening accuracy (mean and maximum distance from straight line), computational time, and robustness to spinal cord length was evaluated using the proposed and the standard straightening method (label‐based spline deformation) on 3T T 2 ‐ and T 1 ‐weighted images from 57 healthy subjects and 33 patients with spinal cord compression due to degenerative cervical myelopathy (DCM). Results: The proposed algorithm was more accurate, more robust, and faster than the standard method (mean distance = 0.80 vs. 0.83 mm, maximum distance = 1.49 vs. 1.78 mm, time = 71 vs. 174 sec for the healthy population and mean distance = 0.65 vs. 0.68 mm, maximum distance = 1.28 vs. 1.55 mm, time = 32 vs. 60 sec for the DCM population). Conclusion: A novel image straightening method that enables template‐based analysis of quantitative spinal cord MRI data is introduced. This algorithm works for any MRI contrast and was validated on healthy and patient populations. The presented method is implemented in the Spinal Cord Toolbox, an open‐source software for processing spinal cord MRI data. Level of Evidence: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1209–1219. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 46:Issue 4(2017)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 46:Issue 4(2017)
- Issue Display:
- Volume 46, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 46
- Issue:
- 4
- Issue Sort Value:
- 2017-0046-0004-0000
- Page Start:
- 1209
- Page End:
- 1219
- Publication Date:
- 2017-01-27
- Subjects:
- spinal cord -- straightening -- deformation field -- NURBS -- SCT -- MR image analysis
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25622 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4687.xml