Using a knowledge-based planning solution to select patients for proton therapy. Issue 2 (August 2017)
- Record Type:
- Journal Article
- Title:
- Using a knowledge-based planning solution to select patients for proton therapy. Issue 2 (August 2017)
- Main Title:
- Using a knowledge-based planning solution to select patients for proton therapy
- Authors:
- Delaney, Alexander R.
Dahele, Max
Tol, Jim P.
Kuijper, Ingrid T.
Slotman, Ben J.
Verbakel, Wilko F.A.R. - Abstract:
- Abstract: Background and purpose: Patient selection for proton therapy by comparing proton/photon treatment plans is time-consuming and prone to bias. RapidPlan™, a knowledge-based-planning solution, uses plan-libraries to model and predict organ-at-risk (OAR) dose-volume-histograms (DVHs). We investigated whether RapidPlan, utilizing an algorithm based only on photon beam characteristics, could generate proton DVH-predictions and whether these could correctly identify patients for proton therapy. Material and methods: ModelPROT and ModelPHOT comprised 30 head-and-neck cancer proton and photon plans, respectively. Proton and photon knowledge-based-plans (KBPs) were made for ten evaluation-patients. DVH-prediction accuracy was analyzed by comparing predicted-vs-achieved mean OAR doses. KBPs and manual plans were compared using salivary gland and swallowing muscle mean doses. For illustration, patients were selected for protons if predicted ModelPHOT mean dose minus predicted ModelPROT mean dose (ΔPrediction) for combined OARs was ≥6 Gy, and benchmarked using achieved KBP doses. Results: Achieved and predicted ModelPROT /ModelPHOT mean dose R 2 was 0.95/0.98. Generally, achieved mean dose for ModelPHOT /ModelPROT KBPs was respectively lower/higher than predicted. Comparing ModelPROT /ModelPHOT KBPs with manual plans, salivary and swallowing mean doses increased/decreased by <2 Gy, on average. ΔPrediction ≥ 6 Gy correctly selected 4 of 5 patients for protons. Conclusions:Abstract: Background and purpose: Patient selection for proton therapy by comparing proton/photon treatment plans is time-consuming and prone to bias. RapidPlan™, a knowledge-based-planning solution, uses plan-libraries to model and predict organ-at-risk (OAR) dose-volume-histograms (DVHs). We investigated whether RapidPlan, utilizing an algorithm based only on photon beam characteristics, could generate proton DVH-predictions and whether these could correctly identify patients for proton therapy. Material and methods: ModelPROT and ModelPHOT comprised 30 head-and-neck cancer proton and photon plans, respectively. Proton and photon knowledge-based-plans (KBPs) were made for ten evaluation-patients. DVH-prediction accuracy was analyzed by comparing predicted-vs-achieved mean OAR doses. KBPs and manual plans were compared using salivary gland and swallowing muscle mean doses. For illustration, patients were selected for protons if predicted ModelPHOT mean dose minus predicted ModelPROT mean dose (ΔPrediction) for combined OARs was ≥6 Gy, and benchmarked using achieved KBP doses. Results: Achieved and predicted ModelPROT /ModelPHOT mean dose R 2 was 0.95/0.98. Generally, achieved mean dose for ModelPHOT /ModelPROT KBPs was respectively lower/higher than predicted. Comparing ModelPROT /ModelPHOT KBPs with manual plans, salivary and swallowing mean doses increased/decreased by <2 Gy, on average. ΔPrediction ≥ 6 Gy correctly selected 4 of 5 patients for protons. Conclusions: Knowledge-based DVH-predictions can provide efficient, patient-specific selection for protons. A proton-specific RapidPlan-solution could improve results. … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 124:Issue 2(2017:Aug.)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 124:Issue 2(2017:Aug.)
- Issue Display:
- Volume 124, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 124
- Issue:
- 2
- Issue Sort Value:
- 2017-0124-0002-0000
- Page Start:
- 263
- Page End:
- 270
- Publication Date:
- 2017-08
- Subjects:
- Proton therapy -- Knowledge-based planning -- Patient selection -- Head and neck cancer
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2017.03.020 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4656.xml