Glottis effects on the cough clearance process simulated with a CFD dynamic mesh and Eulerian wall film model. Issue 12 (10th September 2017)
- Record Type:
- Journal Article
- Title:
- Glottis effects on the cough clearance process simulated with a CFD dynamic mesh and Eulerian wall film model. Issue 12 (10th September 2017)
- Main Title:
- Glottis effects on the cough clearance process simulated with a CFD dynamic mesh and Eulerian wall film model
- Authors:
- Paz, Concepción
Suárez, Eduardo
Parga, Oscar
Vence, Jesús - Abstract:
- Abstract: In this study, we have reproduced the cough clearance process with an Eulerian wall film model. The simulated domain is based on realistic geometry from the literature, which has been improved by adding the glottis and epiglottis. The vocal fold movement has been included due to the dynamic mesh method, considering different abduction and adduction angles and velocities. The proposed methodology captures the deformation of the flexible tissue, considers non-Newtonian properties for the mucus, and enables us to reproduce a single cough or a cough epoch. The cough efficiency (CE) has been used to quantify the overall performance of the cough, considering many different boundary conditions, for the analysis of the glottis effect. It was observed that a viscous shear force is the main mechanism in the cough clearance process, while the glottis closure time and the epiglottis position do not have a significant effect on the CE. The cough assistance devices improve the CE, and the enhancement rate grows logarithmically with the operating pressure. The cough can achieve an effective mucus clearance process, even with a fixed glottis. Nevertheless, the glottis closure substantially improves the CE results.
- Is Part Of:
- Computer methods in biomechanics and biomedical engineering. Volume 20:Issue 12(2017)
- Journal:
- Computer methods in biomechanics and biomedical engineering
- Issue:
- Volume 20:Issue 12(2017)
- Issue Display:
- Volume 20, Issue 12 (2017)
- Year:
- 2017
- Volume:
- 20
- Issue:
- 12
- Issue Sort Value:
- 2017-0020-0012-0000
- Page Start:
- 1326
- Page End:
- 1338
- Publication Date:
- 2017-09-10
- Subjects:
- Glottis -- cough clearance -- Eulerian wall film -- CFD -- epiglottis
Biomechanics -- Data processing -- Periodicals
Biomedical engineering -- Periodicals
Biomechanics -- Periodicals
Biomedical Engineering -- methods -- Periodicals
Computing Methodologies -- Periodicals
612.7 - Journal URLs:
- http://www.tandfonline.com/toc/gcmb20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/10255842.2017.1360872 ↗
- Languages:
- English
- ISSNs:
- 1025-5842
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.100250
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4645.xml