A comparison of two non-invasive methods for measuring scapular orientation in functional positions. (16th August 2017)
- Record Type:
- Journal Article
- Title:
- A comparison of two non-invasive methods for measuring scapular orientation in functional positions. (16th August 2017)
- Main Title:
- A comparison of two non-invasive methods for measuring scapular orientation in functional positions
- Authors:
- Rapp, Elizabeth A.
Richardson, R. Tyler
Russo, Stephanie A.
Rose, William C.
Richards, James G. - Abstract:
- Abstract: Identification of scapular dyskinesis and evaluation of interventions depend on the ability to properly measure scapulothoracic (ST) motion. The most widely used measurement approach is the acromion marker cluster (AMC), which can yield large errors in extreme humeral elevation and can be inaccurate in children and patient populations. Recently, an individualized regression approach has been proposed as an alternative to the AMC. This technique utilizes the relationship between ST orientation, humerothoracic orientation and acromion process position derived from calibration positions to predict dynamic ST orientations from humerothoracic and acromion process measures during motion. These individualized regressions demonstrated promising results for healthy adults; however, this method had not yet been compared to the more conventional AMC. This study compared ST orientation estimates by the AMC and regression approaches to static ST angles determined by surface markers placed on palpated landmarks in typically developing adolescents performing functional tasks. Both approaches produced errors within the range reported in the literature for skin-based scapular measurement techniques. The performance of the regression approach suffered when applied to positions outside of the range of motion in the set of calibration positions. The AMC significantly underestimated ST internal rotation across all positions and overestimated posterior tilt in some positions. Overall,Abstract: Identification of scapular dyskinesis and evaluation of interventions depend on the ability to properly measure scapulothoracic (ST) motion. The most widely used measurement approach is the acromion marker cluster (AMC), which can yield large errors in extreme humeral elevation and can be inaccurate in children and patient populations. Recently, an individualized regression approach has been proposed as an alternative to the AMC. This technique utilizes the relationship between ST orientation, humerothoracic orientation and acromion process position derived from calibration positions to predict dynamic ST orientations from humerothoracic and acromion process measures during motion. These individualized regressions demonstrated promising results for healthy adults; however, this method had not yet been compared to the more conventional AMC. This study compared ST orientation estimates by the AMC and regression approaches to static ST angles determined by surface markers placed on palpated landmarks in typically developing adolescents performing functional tasks. Both approaches produced errors within the range reported in the literature for skin-based scapular measurement techniques. The performance of the regression approach suffered when applied to positions outside of the range of motion in the set of calibration positions. The AMC significantly underestimated ST internal rotation across all positions and overestimated posterior tilt in some positions. Overall, root mean square errors for the regression approach were smaller than the AMC for every position across all axes of ST motion. Accordingly, we recommend the regression approach as a suitable technique for measuring ST kinematics in functional motion. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 61(2017)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 61(2017)
- Issue Display:
- Volume 61, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 61
- Issue:
- 2017
- Issue Sort Value:
- 2017-0061-2017-0000
- Page Start:
- 269
- Page End:
- 274
- Publication Date:
- 2017-08-16
- Subjects:
- Shoulder -- Scapula -- Kinematics -- Measurement -- Cluster -- Regression -- Adolescent
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2017.07.032 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4617.xml