Treatment of the Fixation Surface Improves Glenoid Prosthesis Longevity in vitro. (16th August 2017)
- Record Type:
- Journal Article
- Title:
- Treatment of the Fixation Surface Improves Glenoid Prosthesis Longevity in vitro. (16th August 2017)
- Main Title:
- Treatment of the Fixation Surface Improves Glenoid Prosthesis Longevity in vitro
- Authors:
- Junaid, Sarah
Sanghavi, Sanjay
Anglin, Carolyn
Bull, Anthony
Emery, Roger
Amis, Andrew A.
Hansen, Ulrich - Abstract:
- Abstract: Many commercial cemented glenoid components claim superior fixation designs and increased survivability. However, both research and clinical studies have shown conflicting results and it is unclear whether these design variations do improve loosening rates. Part of the difficulty in investigating fixation failure is the inability to directly observe the fixation interface, a problem addressed in this study by using a novel experimental set-up. Cyclic loading-displacement tests were carried out on 60 custom-made glenoid prostheses implanted into a bone substitute. Design parameters investigated included treatment of the fixation surface of the component resulting in different levels of back-surface roughness, flat-back versus curved-back, keel versus peg and more versus less conforming implants. Visually-observed failure and ASTM-recommended rim-displacements were recorded throughout testing to investigate fixation failure and if rim displacement is an appropriate measure of loosening. Roughening the implant back (Ra > 3 µm) improved resistance to failure (P < 0.005) by an order of magnitude with the rough and smooth groups failing at 8712 ± 5584 cycles (mean ± SD) and 1080 ± 1197 cycles, respectively. All other design parameters had no statistically significant effect on the number of cycles to failure. All implants failed inferiorly and 95% (57/60) at the implant/cement interface. Rim-displacement correlated with visually observed failure. The most importantAbstract: Many commercial cemented glenoid components claim superior fixation designs and increased survivability. However, both research and clinical studies have shown conflicting results and it is unclear whether these design variations do improve loosening rates. Part of the difficulty in investigating fixation failure is the inability to directly observe the fixation interface, a problem addressed in this study by using a novel experimental set-up. Cyclic loading-displacement tests were carried out on 60 custom-made glenoid prostheses implanted into a bone substitute. Design parameters investigated included treatment of the fixation surface of the component resulting in different levels of back-surface roughness, flat-back versus curved-back, keel versus peg and more versus less conforming implants. Visually-observed failure and ASTM-recommended rim-displacements were recorded throughout testing to investigate fixation failure and if rim displacement is an appropriate measure of loosening. Roughening the implant back (Ra > 3 µm) improved resistance to failure (P < 0.005) by an order of magnitude with the rough and smooth groups failing at 8712 ± 5584 cycles (mean ± SD) and 1080 ± 1197 cycles, respectively. All other design parameters had no statistically significant effect on the number of cycles to failure. All implants failed inferiorly and 95% (57/60) at the implant/cement interface. Rim-displacement correlated with visually observed failure. The most important effect was that of roughening the implant, which strengthened the polyethylene-cement interface. Rim-displacement can be used as an indicator of fixation failure, but the sensitivity was insufficient to capture subtle effects. Level of Evidence: Basic Science Study, Biomechanical Analysis. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 61(2017)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 61(2017)
- Issue Display:
- Volume 61, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 61
- Issue:
- 2017
- Issue Sort Value:
- 2017-0061-2017-0000
- Page Start:
- 81
- Page End:
- 87
- Publication Date:
- 2017-08-16
- Subjects:
- Glenoid -- Loosening -- Fixation failure -- Design -- Roughness -- Total shoulder arthroplasty
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2017.07.008 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4617.xml