Experimental Assessment of Physician Modified Proximal Scalloped Stent Graft to Extend Proximal Landing Zone in the Aortic Arch. (August 2017)
- Record Type:
- Journal Article
- Title:
- Experimental Assessment of Physician Modified Proximal Scalloped Stent Graft to Extend Proximal Landing Zone in the Aortic Arch. (August 2017)
- Main Title:
- Experimental Assessment of Physician Modified Proximal Scalloped Stent Graft to Extend Proximal Landing Zone in the Aortic Arch
- Authors:
- Faure, E.M.
Khantalin, I.
Peyron, P.A.
Canaud, L.
Marty-Ané, C.
Alric, P. - Abstract:
- Abstract : Objective/Background: The aim of the study was to assess a model of physician modified scalloped stent graft (PMSG) on currently available thoracic aortic devices to extend the proximal landing zone in either zone 2, 1 or 0 of the aortic arch while preserving flow in the supra-aortic vessels on human cadaveric aorta. Methods: Fresh human aortas were harvested at autopsy from adult subjects. A proximal scallop was made on the stent grafts based on direct measurements on the aortas to extend the proximal landing zone in zone 0 ( n = 5), zone 1 ( n = 5), and zone 2 ( n = 5). A previously described benchtop closed system pulsatile flow model was used to mimic flow and pressure conditions in the aorta to deploy the stent graft as close to physiological conditions as possible. Deployment accuracy of the scallop opposite the aortic arch branch ostia was assessed by completion angiography and post-procedural analysis of the aortas. Results: Fifteen proximal scalloped stent grafts were deployed in the aortic arch of 15 human cadaveric aortas under fluoroscopy. The expected proximal landing zone was achieved in all cases (zone 2 = 5; zone 1 = 5; zone 0 = 5). Post-procedural angiography and direct visual analysis showed supra-aortic vessel patency and deployment of the scallop opposite the aortic arch branch ostia in all cases. Conclusion: PMSG to extend the proximal landing zone in zone 2, 1, or 0 in order to treat urgent diseases of the proximal descending aorta or theAbstract : Objective/Background: The aim of the study was to assess a model of physician modified scalloped stent graft (PMSG) on currently available thoracic aortic devices to extend the proximal landing zone in either zone 2, 1 or 0 of the aortic arch while preserving flow in the supra-aortic vessels on human cadaveric aorta. Methods: Fresh human aortas were harvested at autopsy from adult subjects. A proximal scallop was made on the stent grafts based on direct measurements on the aortas to extend the proximal landing zone in zone 0 ( n = 5), zone 1 ( n = 5), and zone 2 ( n = 5). A previously described benchtop closed system pulsatile flow model was used to mimic flow and pressure conditions in the aorta to deploy the stent graft as close to physiological conditions as possible. Deployment accuracy of the scallop opposite the aortic arch branch ostia was assessed by completion angiography and post-procedural analysis of the aortas. Results: Fifteen proximal scalloped stent grafts were deployed in the aortic arch of 15 human cadaveric aortas under fluoroscopy. The expected proximal landing zone was achieved in all cases (zone 2 = 5; zone 1 = 5; zone 0 = 5). Post-procedural angiography and direct visual analysis showed supra-aortic vessel patency and deployment of the scallop opposite the aortic arch branch ostia in all cases. Conclusion: PMSG to extend the proximal landing zone in zone 2, 1, or 0 in order to treat urgent diseases of the proximal descending aorta or the inner circumference of the aortic arch by a totally endovascular approach while preserving flow in the supra-aortic trunks is experimentally feasible. … (more)
- Is Part Of:
- European journal of vascular and endovascular surgery. Volume 54:Number 2(2017)
- Journal:
- European journal of vascular and endovascular surgery
- Issue:
- Volume 54:Number 2(2017)
- Issue Display:
- Volume 54, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 54
- Issue:
- 2
- Issue Sort Value:
- 2017-0054-0002-0000
- Page Start:
- 150
- Page End:
- 156
- Publication Date:
- 2017-08
- Subjects:
- Acute aortic syndrome -- Aortic arch -- Scallop -- Thoracic stent graft
Blood-vessels -- Endoscopic surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Vascular Surgical Procedures -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Vaisseaux sanguins -- Chirurgie -- Périodiques
Vaisseaux sanguins -- Chirurgie endoscopique -- Périodiques
Blood-vessels -- Endoscopic surgery
Blood-vessels -- Surgery
Endoscopy
Electronic journals
Periodicals
Electronic journals
617.413005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1078-5884;screen=info;ECOIP ↗
http://www.harcourt-international.com/journals/ejvs/ ↗
http://www.harcourt-international.com/journals/ejvx/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10785884 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10785884 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejvs.2017.04.019 ↗
- Languages:
- English
- ISSNs:
- 1078-5884
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.747280
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4633.xml