Textile Aging Characterization on New Generations of Explanted Commercial Endoprostheses: A Preliminary Study. (September 2017)
- Record Type:
- Journal Article
- Title:
- Textile Aging Characterization on New Generations of Explanted Commercial Endoprostheses: A Preliminary Study. (September 2017)
- Main Title:
- Textile Aging Characterization on New Generations of Explanted Commercial Endoprostheses: A Preliminary Study
- Authors:
- Albertini, J.-N.
Favre, J.-P.
Duprey, A.
Anidjar, S.
Battelier, J.
Chabert, S.
Chiesa, R.
Corpataux, J.-M.
Deglise, S.
Daligault, M.
Picquet, J.
Sebastian Debus, E.
David, N.
Plissonnier, D.
Favier, C.
Steinmetz, É.
Feugier, P.
Lermusiaux, P.
Goueffic, Y.
Kaladji, A.
Querat, J.
Guigard, S.
Magne, J.-L.
Hassen-Khodja, R.
Jean-Baptiste, E.
Jirari, A.
Koskas, F.
Piquet, P.
Bussmann, A.
Heim, F.
Delay, C.
Girsowicz, E.
Del Tatto, B.
Dion, D.
Papillon, J.
Lejay, A.
Chakfé, J.
Thaveau, F.
Georg, Y.
Chakfé, N.
… (more) - Abstract:
- Abstract : Objective/background: The goal of the present study was to assess the aging phenomena on second-generation textile endoprostheses (EPs) through explant analysis and to establish a preliminary classification of observed defects and material damages. Methods: From January 2011 to June 2016 110 second- and recent-generation EPs were collected as a part of a European collaborative retrieval program. The analysis focused on the first 41 consecutive commercial EPs collected between 2011 and 2014 and made from polyethylene terephthalate. Explants were submitted to a standardized evaluation protocol, which included data recording, eye-naked evaluation, cleaning of organic remnants, and structural analysis under numerical optical microscopy. Observations were reported using a classification based on 15 features evaluating the fabric, the stitches between the fabric and the stents, and the stents. The total surface area of the holes within the fabric was measured. Results: EPs were implanted for thoracic and abdominal procedures in 12 and 29 cases, respectively. The mean ± SD duration of implantation was 34 ± 26 months (range 2 days–8 years). Sixty-four percent of the samples demonstrated at least one defect caused by compression damage potentially related to the insertion of the EP within the delivery system, which promoted holes and tears. Ninety-five percent of all EPs demonstrated at least one type of abrasion on the stitches. The degradation of the stitches and theAbstract : Objective/background: The goal of the present study was to assess the aging phenomena on second-generation textile endoprostheses (EPs) through explant analysis and to establish a preliminary classification of observed defects and material damages. Methods: From January 2011 to June 2016 110 second- and recent-generation EPs were collected as a part of a European collaborative retrieval program. The analysis focused on the first 41 consecutive commercial EPs collected between 2011 and 2014 and made from polyethylene terephthalate. Explants were submitted to a standardized evaluation protocol, which included data recording, eye-naked evaluation, cleaning of organic remnants, and structural analysis under numerical optical microscopy. Observations were reported using a classification based on 15 features evaluating the fabric, the stitches between the fabric and the stents, and the stents. The total surface area of the holes within the fabric was measured. Results: EPs were implanted for thoracic and abdominal procedures in 12 and 29 cases, respectively. The mean ± SD duration of implantation was 34 ± 26 months (range 2 days–8 years). Sixty-four percent of the samples demonstrated at least one defect caused by compression damage potentially related to the insertion of the EP within the delivery system, which promoted holes and tears. Ninety-five percent of all EPs demonstrated at least one type of abrasion on the stitches. The degradation of the stitches and the number of ruptures increased with duration of implantation. Stent degradation was rare and consisted of corrosion and rupture. Cumulated holed surface area increased with time and was measured up to 13.5 mm 2 . Conclusion: Various aging-related phenomena on commercial textile EPs were identified and classified. Main damaging mechanisms were related to compression and abrasion leading to tears and holes in the fabric and rupture of stitches. … (more)
- Is Part Of:
- European journal of vascular and endovascular surgery. Volume 54:Number 3(2017)
- Journal:
- European journal of vascular and endovascular surgery
- Issue:
- Volume 54:Number 3(2017)
- Issue Display:
- Volume 54, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 54
- Issue:
- 3
- Issue Sort Value:
- 2017-0054-0003-0000
- Page Start:
- 378
- Page End:
- 386
- Publication Date:
- 2017-09
- Subjects:
- Aortic endoprostheses -- Degradation -- Polyester -- Textile -- Stent
Blood-vessels -- Endoscopic surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Vascular Surgical Procedures -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Vaisseaux sanguins -- Chirurgie -- Périodiques
Vaisseaux sanguins -- Chirurgie endoscopique -- Périodiques
Blood-vessels -- Endoscopic surgery
Blood-vessels -- Surgery
Endoscopy
Electronic journals
Periodicals
Electronic journals
617.413005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1078-5884;screen=info;ECOIP ↗
http://www.harcourt-international.com/journals/ejvs/ ↗
http://www.harcourt-international.com/journals/ejvx/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10785884 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10785884 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejvs.2017.06.004 ↗
- Languages:
- English
- ISSNs:
- 1078-5884
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.747280
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4641.xml