Design of experiments in medical physics: Application to the AAA beam model validation. (September 2017)
- Record Type:
- Journal Article
- Title:
- Design of experiments in medical physics: Application to the AAA beam model validation. (September 2017)
- Main Title:
- Design of experiments in medical physics: Application to the AAA beam model validation
- Authors:
- Dufreneix, S.
Legrand, C.
Di Bartolo, C.
Bremaud, M.
Mesgouez, J.
Tiplica, T.
Autret, D. - Abstract:
- Highlights: Experimental designs offer a fast and robust method for algorithm validation. Only 72 tests are necessary to validate a beam model. Statistical analysis reveals non-clinically significant differences. Experimental designs could be largely used in medical physics. Abstract: Purpose: The purpose of this study is to evaluate the usefulness of the design of experiments in the analysis of multiparametric problems related to the quality assurance in radiotherapy. The main motivation is to use this statistical method to optimize the quality assurance processes in the validation of beam models. Method: Considering the Varian Eclipse system, eight parameters with several levels were selected: energy, MLC, depth, X, Y1 and Y2 jaw dimensions, wedge and wedge jaw. A Taguchi table was used to define 72 validation tests. Measurements were conducted in water using a CC04 on a TrueBeam STx, a TrueBeam Tx, a Trilogy and a 2300IX accelerator matched by the vendor. Dose was computed using the AAA algorithm. The same raw data was used for all accelerators during the beam modelling. Results: The mean difference between computed and measured doses was 0.1 ± 0.5% for all beams and all accelerators with a maximum difference of 2.4% (under the 3% tolerance level). For all beams, the measured doses were within 0.6% for all accelerators. The energy was found to be an influencing parameter but the deviations observed were smaller than 1% and not considered clinically significant.Highlights: Experimental designs offer a fast and robust method for algorithm validation. Only 72 tests are necessary to validate a beam model. Statistical analysis reveals non-clinically significant differences. Experimental designs could be largely used in medical physics. Abstract: Purpose: The purpose of this study is to evaluate the usefulness of the design of experiments in the analysis of multiparametric problems related to the quality assurance in radiotherapy. The main motivation is to use this statistical method to optimize the quality assurance processes in the validation of beam models. Method: Considering the Varian Eclipse system, eight parameters with several levels were selected: energy, MLC, depth, X, Y1 and Y2 jaw dimensions, wedge and wedge jaw. A Taguchi table was used to define 72 validation tests. Measurements were conducted in water using a CC04 on a TrueBeam STx, a TrueBeam Tx, a Trilogy and a 2300IX accelerator matched by the vendor. Dose was computed using the AAA algorithm. The same raw data was used for all accelerators during the beam modelling. Results: The mean difference between computed and measured doses was 0.1 ± 0.5% for all beams and all accelerators with a maximum difference of 2.4% (under the 3% tolerance level). For all beams, the measured doses were within 0.6% for all accelerators. The energy was found to be an influencing parameter but the deviations observed were smaller than 1% and not considered clinically significant. Conclusion: Designs of experiment can help define the optimal measurement set to validate a beam model. The proposed method can be used to identify the prognostic factors of dose accuracy. The beam models were validated for the 4 accelerators which were found dosimetrically equivalent even though the accelerator characteristics differ. … (more)
- Is Part Of:
- Physica medica. Volume 41(2017)
- Journal:
- Physica medica
- Issue:
- Volume 41(2017)
- Issue Display:
- Volume 41, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 41
- Issue:
- 2017
- Issue Sort Value:
- 2017-0041-2017-0000
- Page Start:
- 26
- Page End:
- 32
- Publication Date:
- 2017-09
- Subjects:
- Experimental designs -- Quality assurance -- Beam model
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2017.05.068 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4623.xml