P 105 Spatio-temporal characteristics of somatosensory-evoked high-gamma activity of the EEG. Issue 10 (October 2017)
- Record Type:
- Journal Article
- Title:
- P 105 Spatio-temporal characteristics of somatosensory-evoked high-gamma activity of the EEG. Issue 10 (October 2017)
- Main Title:
- P 105 Spatio-temporal characteristics of somatosensory-evoked high-gamma activity of the EEG
- Authors:
- Kahle, L.
Contzen, S.
Fiederer, L.
Völker, M.
Kellmeyer, P.
Ball, T. - Abstract:
- Abstract : Introduction: There is enlarging interest in the cortical function of high gamma band (HGB) changes related to different sensory modalities, movement tasks, and higher cognitive processes. EEG experiments have shown visually-evoked, auditory-evoked, and movement-related HGB changes, including the range of 50–70 Hz (Tallon-Baudry et al., 1997; Ball et al., 2008 ). While HGB activity in this frequency range associated to peripheral somatosensory stimulation was reported for intracranial recordings in neurological patients (Fukuda et al., 2008 ), it has received little attention in EEG studies. Here the focus was on very high frequency somatosensory responses above 600 Hz (Curio et al., 1994 ). In the present study, we implemented an experimental setup, optimized to measure high frequencies in the EEG, to investigate if robust 50–70 Hz HGB activity in noninvasive EEG could be identified during median nerve SEP stimulation and what the spatio-temporal characteristics of these changes are. Methods: In an electromagnetically-shielded cabin, EEG data of 15 healthy subjects was obtained with 128 Ag/AgCl scalp electrodes and with NeurOne amplifiers (24-bit digital resolution and 5 kHz sampling rate). 1200 SEPs per subject were evoked by stimulation of the left median nerve with a SEP-stimulator. Simultaneous eye-tracking data from 7 of these subjects was attained to examine the influence of ocular movements on the neuronal recordings. Data analysis included preprocessing,Abstract : Introduction: There is enlarging interest in the cortical function of high gamma band (HGB) changes related to different sensory modalities, movement tasks, and higher cognitive processes. EEG experiments have shown visually-evoked, auditory-evoked, and movement-related HGB changes, including the range of 50–70 Hz (Tallon-Baudry et al., 1997; Ball et al., 2008 ). While HGB activity in this frequency range associated to peripheral somatosensory stimulation was reported for intracranial recordings in neurological patients (Fukuda et al., 2008 ), it has received little attention in EEG studies. Here the focus was on very high frequency somatosensory responses above 600 Hz (Curio et al., 1994 ). In the present study, we implemented an experimental setup, optimized to measure high frequencies in the EEG, to investigate if robust 50–70 Hz HGB activity in noninvasive EEG could be identified during median nerve SEP stimulation and what the spatio-temporal characteristics of these changes are. Methods: In an electromagnetically-shielded cabin, EEG data of 15 healthy subjects was obtained with 128 Ag/AgCl scalp electrodes and with NeurOne amplifiers (24-bit digital resolution and 5 kHz sampling rate). 1200 SEPs per subject were evoked by stimulation of the left median nerve with a SEP-stimulator. Simultaneous eye-tracking data from 7 of these subjects was attained to examine the influence of ocular movements on the neuronal recordings. Data analysis included preprocessing, short-time Fourier transformation algorithm, normalization, calculation of induced and evoked responses and a false discovery rate corrected sign test. Results: All analyzed subjects showed a significant spectral power increase in the HGB range at 50–70 Hz after median nerve stimulation ( p < 0.01, FDR corrected sign test). This HGB activity occurred at contralateral electrode positions electrodes with most pronounced effects at the centro-parietal electrodes CCP4h, CP4 and CPP4h and was not associated with eye movement artefacts. The identified activity pattern changed characteristically over time and frequency: Contralateral frontal electrodes (FFC4h, FC2, FC4, FCC4h) showed a power increase in lower frequencies (30–50 Hz) and later time windows (20–60 ms), while activity of contralateral centro-parietal and parietal electrodes (CP4, CPP4h, P4, C2) started earlier (10–20 ms) and was detectable in higher frequencies (40–90 Hz). The HGB activity consisted of a high-intensity phase-locked response and a low-intensity non-phase-locked response. Conclusion: Using our purpose-build experimental set up, we were able to demonstrate a specific contralateral somatosensory-evoked response pattern in the 50–70-Hz frequency range of the noninvasive EEG. Our results agree with the findings of previous intracranial SEP studies and open up new possibilities to noninvasively study sensory related brain functions, both in healthy subjects and neurological patients. … (more)
- Is Part Of:
- Clinical neurophysiology. Volume 128:Issue 10(2017:Oct.)
- Journal:
- Clinical neurophysiology
- Issue:
- Volume 128:Issue 10(2017:Oct.)
- Issue Display:
- Volume 128, Issue 10 (2017)
- Year:
- 2017
- Volume:
- 128
- Issue:
- 10
- Issue Sort Value:
- 2017-0128-0010-0000
- Page Start:
- e381
- Page End:
- Publication Date:
- 2017-10
- Subjects:
- Neurophysiology -- Periodicals
Electroencephalography -- Periodicals
Electromyography -- Periodicals
Neurology -- Periodicals
612.8 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13882457 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinph.2017.06.180 ↗
- Languages:
- English
- ISSNs:
- 1388-2457
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.310645
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4638.xml