Fixed and mobile-bearing total ankle prostheses: Effect on tibial bone strain. (October 2017)
- Record Type:
- Journal Article
- Title:
- Fixed and mobile-bearing total ankle prostheses: Effect on tibial bone strain. (October 2017)
- Main Title:
- Fixed and mobile-bearing total ankle prostheses: Effect on tibial bone strain
- Authors:
- Terrier, Alexandre
Fernandes, Caroline Sieger
Guillemin, Maïka
Crevoisier, Xavier - Abstract:
- Abstract: Background: Total ankle replacement is associated to a high revision rate. To improve implant survival, the potential advantage of prostheses with fixed bearing compared to mobile bearing is unclear. The objective of this study was to test the hypothesis that fixed and mobile bearing prostheses are associated with different biomechanical quantities typically associated to implant failure. Methods: With a validated finite element model, we compared three cases: a prosthesis with a fixed bearing, a prosthesis with a mobile bearing in a centered position, and a prosthesis with mobile bearing in an eccentric position. Both prostheses were obtained from the same manufacturer. They were tested on seven tibias with maximum axial compression force during walking. We tested the hypothesis that there was a difference of bone strain, bone-implant interfacial stress, and bone support between the three cases. We also evaluated, for the three cases, the correlations between bone support, bone strain and bone-implant interfacial stress. Findings: There were no statistically significant differences between the three cases. Overall, bone support was mainly trabecular, and less effective in the posterior side. Bone strain and bone-implant interfacial stress were strongly correlated to bone support. Interpretations: Even if slight differences are observed between fixed and mobile bearing, it is not enough to put forward the superiority of one of these implants regarding theirAbstract: Background: Total ankle replacement is associated to a high revision rate. To improve implant survival, the potential advantage of prostheses with fixed bearing compared to mobile bearing is unclear. The objective of this study was to test the hypothesis that fixed and mobile bearing prostheses are associated with different biomechanical quantities typically associated to implant failure. Methods: With a validated finite element model, we compared three cases: a prosthesis with a fixed bearing, a prosthesis with a mobile bearing in a centered position, and a prosthesis with mobile bearing in an eccentric position. Both prostheses were obtained from the same manufacturer. They were tested on seven tibias with maximum axial compression force during walking. We tested the hypothesis that there was a difference of bone strain, bone-implant interfacial stress, and bone support between the three cases. We also evaluated, for the three cases, the correlations between bone support, bone strain and bone-implant interfacial stress. Findings: There were no statistically significant differences between the three cases. Overall, bone support was mainly trabecular, and less effective in the posterior side. Bone strain and bone-implant interfacial stress were strongly correlated to bone support. Interpretations: Even if slight differences are observed between fixed and mobile bearing, it is not enough to put forward the superiority of one of these implants regarding their reaction to axial compression. When associated to the published clinical results, our study provides no argument to warn surgeons against the use of two-components fixed bearing implants. Highlights: Finite element analysis of ankle arthroplasty to compare fixed and mobile insert No significant ( n = 7) differences in bone strain Strong correlation between bone strain and bone support … (more)
- Is Part Of:
- Clinical biomechanics. Volume 48(2017)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 48(2017)
- Issue Display:
- Volume 48, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 48
- Issue:
- 2017
- Issue Sort Value:
- 2017-0048-2017-0000
- Page Start:
- 57
- Page End:
- 62
- Publication Date:
- 2017-10
- Subjects:
- Ankle -- Arthroplasty -- Mobile bearing -- Fixed bearing -- Finite element method
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2017.07.009 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4643.xml