Development and evaluation of a building integrated aquifer thermal storage model. (5th November 2017)
- Record Type:
- Journal Article
- Title:
- Development and evaluation of a building integrated aquifer thermal storage model. (5th November 2017)
- Main Title:
- Development and evaluation of a building integrated aquifer thermal storage model
- Authors:
- Bozkaya, Basar
Li, Rongling
Labeodan, Timilehin
Kramer, Rick
Zeiler, Wim - Abstract:
- Highlights: The previous aquifer thermal energy storage (ATES) models are investigated. An ATES model was developed using the co-simulation between MATLAB and COMSOL. The developed ATES model was validated with an experimental data from an operational ATES in the Netherlands. Abstract: An aquifer thermal energy storage (ATES) in combination with a heat pump is an excellent way to reduce the net energy usage of buildings. The use of ATES has been demonstrated to have the potential to provide a reduction of between 20 and 40% in the cooling and heating energy use of buildings. ATES systems are however a complex system to analyse as a number of ground conditions influence heat losses within the aquifer. ATES is also not confined from the sides and is therefore vulnerable to heat losses through conduction, advection and dispersion. The analyses of ATES system is even further complicated when the dynamic of a building is considered. When connected to a building, the temperature in the aquifer is influenced by the amount of heat exchange with the varying building load. Given the energy saving potentials of ATES systems in building operation, detailed understanding of the influence of buildings on the ATES systems and vice versa would facilitate improved operation and efficiency of ATES and building coupled systems. Therefore, taking into account the variations in the building and below ground conditions, there is the need for the development of a model that can potentially handleHighlights: The previous aquifer thermal energy storage (ATES) models are investigated. An ATES model was developed using the co-simulation between MATLAB and COMSOL. The developed ATES model was validated with an experimental data from an operational ATES in the Netherlands. Abstract: An aquifer thermal energy storage (ATES) in combination with a heat pump is an excellent way to reduce the net energy usage of buildings. The use of ATES has been demonstrated to have the potential to provide a reduction of between 20 and 40% in the cooling and heating energy use of buildings. ATES systems are however a complex system to analyse as a number of ground conditions influence heat losses within the aquifer. ATES is also not confined from the sides and is therefore vulnerable to heat losses through conduction, advection and dispersion. The analyses of ATES system is even further complicated when the dynamic of a building is considered. When connected to a building, the temperature in the aquifer is influenced by the amount of heat exchange with the varying building load. Given the energy saving potentials of ATES systems in building operation, detailed understanding of the influence of buildings on the ATES systems and vice versa would facilitate improved operation and efficiency of ATES and building coupled systems. Therefore, taking into account the variations in the building and below ground conditions, there is the need for the development of a model that can potentially handle the dynamics on both sides. Finite element and finite volume methods are frequently used in the development of ATES models and proven as adequate tools for modelling complex ground conditions, however, most developed ATES models are often analysed independent of the building. Therefore, in this study, an ATES model that also integrates building dynamics is developed using the finite element method (FEM). The developed model was validated using data from an ATES and building in the Netherlands. The developed model was shown to have an absolute mean error of 0.17 °C and 0.12 °C for the cold and warm wells respectively. … (more)
- Is Part Of:
- Applied thermal engineering. Volume 126(2017)
- Journal:
- Applied thermal engineering
- Issue:
- Volume 126(2017)
- Issue Display:
- Volume 126, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 126
- Issue:
- 2017
- Issue Sort Value:
- 2017-0126-2017-0000
- Page Start:
- 620
- Page End:
- 629
- Publication Date:
- 2017-11-05
- Subjects:
- Aquifer thermal energy storage -- Aquifer thermal modelling -- Building integrated ATES
Heat engineering -- Periodicals
Heating -- Equipment and supplies -- Periodicals
Periodicals
621.40205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13594311 ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.applthermaleng.2017.07.195 ↗
- Languages:
- English
- ISSNs:
- 1359-4311
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1580.101000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4616.xml