Important factors affecting the thermal resistance and thermal diffusivity of vapor chambers. (5th November 2017)
- Record Type:
- Journal Article
- Title:
- Important factors affecting the thermal resistance and thermal diffusivity of vapor chambers. (5th November 2017)
- Main Title:
- Important factors affecting the thermal resistance and thermal diffusivity of vapor chambers
- Authors:
- Huang, Chien
Lin, Wei-Keng
Chen, Jhe-Kai - Abstract:
- Highlights: Comparison of thermal resistance in vapor chambers under various types of Experiment Setup. The lowest resistance was observed for VC under constant temperature conditions. Measurement of thermal diffusivity in vapor chamber using the Angstrom method. Thermal diffusivity of vapor chamber was 36 times higher than that of copper plate. Abstract: This paper discusses a number of important parameters associated with the measurement of thermal resistance and thermal diffusivity in vapor chambers (VCs). Thermal resistance and thermal diffusivity are representative indicators of VC performance. In this paper, we measured thermal resistance using four distinct Experiment Setups. Our empirical results demonstrate that thermal resistance values depend largely on how the experiment is set up. We also examined two different condensation methods in the measurement of thermal resistance. Condensation condition 1 uses cooling water with an input temperature fixed at 20 °C and the flow rate fixed at 10 g/s. Condition 2 involved fixing the temperature of the top surface of the vapor chamber by adjusting the temperature of the cooling water according to the input power. In experiments, the lowest thermal resistance was 0.135 °C/W under condensation condition 1 and 0.023 °C/W under condensation condition 2. We also developed a device for the measurement of thermal diffusivity based on the Angstrom method. We then measured (under experimental conditions) the thermal diffusivity ofHighlights: Comparison of thermal resistance in vapor chambers under various types of Experiment Setup. The lowest resistance was observed for VC under constant temperature conditions. Measurement of thermal diffusivity in vapor chamber using the Angstrom method. Thermal diffusivity of vapor chamber was 36 times higher than that of copper plate. Abstract: This paper discusses a number of important parameters associated with the measurement of thermal resistance and thermal diffusivity in vapor chambers (VCs). Thermal resistance and thermal diffusivity are representative indicators of VC performance. In this paper, we measured thermal resistance using four distinct Experiment Setups. Our empirical results demonstrate that thermal resistance values depend largely on how the experiment is set up. We also examined two different condensation methods in the measurement of thermal resistance. Condensation condition 1 uses cooling water with an input temperature fixed at 20 °C and the flow rate fixed at 10 g/s. Condition 2 involved fixing the temperature of the top surface of the vapor chamber by adjusting the temperature of the cooling water according to the input power. In experiments, the lowest thermal resistance was 0.135 °C/W under condensation condition 1 and 0.023 °C/W under condensation condition 2. We also developed a device for the measurement of thermal diffusivity based on the Angstrom method. We then measured (under experimental conditions) the thermal diffusivity of four pure metals for comparison with standard reference values. The thermal diffusivity values were measured as follows: VC (44.04 cm 2 /s) and copper plate (1.219 cm 2 /s). … (more)
- Is Part Of:
- Applied thermal engineering. Volume 126(2017)
- Journal:
- Applied thermal engineering
- Issue:
- Volume 126(2017)
- Issue Display:
- Volume 126, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 126
- Issue:
- 2017
- Issue Sort Value:
- 2017-0126-2017-0000
- Page Start:
- 1148
- Page End:
- 1155
- Publication Date:
- 2017-11-05
- Subjects:
- Vapor chamber -- Thermal resistance -- Thermal diffusivity -- Angstrom method
Heat engineering -- Periodicals
Heating -- Equipment and supplies -- Periodicals
Periodicals
621.40205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13594311 ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.applthermaleng.2016.12.106 ↗
- Languages:
- English
- ISSNs:
- 1359-4311
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1580.101000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4615.xml