Simultaneous Multislice–Based 5‐Minute Lumbar Spine MRI Protocol: Initial Experience in a Clinical Setting. Issue 5 (2nd June 2017)
- Record Type:
- Journal Article
- Title:
- Simultaneous Multislice–Based 5‐Minute Lumbar Spine MRI Protocol: Initial Experience in a Clinical Setting. Issue 5 (2nd June 2017)
- Main Title:
- Simultaneous Multislice–Based 5‐Minute Lumbar Spine MRI Protocol: Initial Experience in a Clinical Setting
- Authors:
- Longo, Maria G.
Fagundes, Joana
Huang, Susie
Mehan, William
Witzel, Thomas
Bhat, Himanshu
Heberlein, Keith
Rosen, Bruce R.
Rosenthal, Daniel
Gonzalez, Ramon G.
Schaefer, Pamela W.
Rapalino, Otto - Abstract:
- ABSTRACT: BACKGROUND AND PURPOSE: Previous studies have used parallel imaging (PI) techniques to decrease spine magnetic resonance imaging (MRI) protocol acquisition times. Recently developed MRI sequences allow even faster acquisitions. Our purpose was to develop a lumbar spine MRI protocol using PI with GRAPPA (generalized autocalibrating partially parallel acquisition) and a simultaneous multislice (SMS)–based sequence and to evaluate its diagnostic performance compared to a standard lumbar spine MRI protocol. METHODS: Ten patients were scanned in a 3‐Tesla scanner (MAGNETOM Skyra, Siemens Healthcare). Each patient was imaged using a standard protocol and an optimized fast protocol acquiring the same contrasts and planes. The fast protocol included sagittal T1, T2, and fat suppressed T2 sequences accelerated with GRAPPA and an SMS‐based axial T2‐weighted sequence using a high‐density spine coil (Siemens MR, 30 channel spine). Two blinded neuroradiologists independently assessed image quality and diagnostic accuracy for clinically relevant imaging findings. RESULTS: The fast protocol acquisition time was 5:28 minutes, compared with 16:30 minutes for the standard protocol. Both protocols had a similar performance for definition of anatomical structures, diagnostic quality, and identification of clinically relevant imaging findings. There were more artifacts in the SMS Turbo Spin Echo ( P = .014) sequence without compromising diagnostic performance. Artifacts in theABSTRACT: BACKGROUND AND PURPOSE: Previous studies have used parallel imaging (PI) techniques to decrease spine magnetic resonance imaging (MRI) protocol acquisition times. Recently developed MRI sequences allow even faster acquisitions. Our purpose was to develop a lumbar spine MRI protocol using PI with GRAPPA (generalized autocalibrating partially parallel acquisition) and a simultaneous multislice (SMS)–based sequence and to evaluate its diagnostic performance compared to a standard lumbar spine MRI protocol. METHODS: Ten patients were scanned in a 3‐Tesla scanner (MAGNETOM Skyra, Siemens Healthcare). Each patient was imaged using a standard protocol and an optimized fast protocol acquiring the same contrasts and planes. The fast protocol included sagittal T1, T2, and fat suppressed T2 sequences accelerated with GRAPPA and an SMS‐based axial T2‐weighted sequence using a high‐density spine coil (Siemens MR, 30 channel spine). Two blinded neuroradiologists independently assessed image quality and diagnostic accuracy for clinically relevant imaging findings. RESULTS: The fast protocol acquisition time was 5:28 minutes, compared with 16:30 minutes for the standard protocol. Both protocols had a similar performance for definition of anatomical structures, diagnostic quality, and identification of clinically relevant imaging findings. There were more artifacts in the SMS Turbo Spin Echo ( P = .014) sequence without compromising diagnostic performance. Artifacts in the remaining non‐SMS sequences were similar in both protocols ( P > .180). The sensitivity, specificity, and accuracy of the 5‐minute protocol were 92.3%, 100.0%, and 99.6%, respectively, for the clinically relevant findings ( P = 1.0, interrater agreement .57). CONCLUSIONS: A 5‐minute SMS‐based MRI protocol for lumbar spine imaging is feasible and can be achieved without significant impact in the overall diagnostic quality. … (more)
- Is Part Of:
- Journal of neuroimaging. Volume 27:Issue 5(2017)
- Journal:
- Journal of neuroimaging
- Issue:
- Volume 27:Issue 5(2017)
- Issue Display:
- Volume 27, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 27
- Issue:
- 5
- Issue Sort Value:
- 2017-0027-0005-0000
- Page Start:
- 442
- Page End:
- 446
- Publication Date:
- 2017-06-02
- Subjects:
- Lumbar spine MRI -- simultaneous multislice -- parallel imaging
Diagnostic imaging -- Periodicals
Nervous system -- Diseases -- Diagnosis -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Système nerveux -- Maladies -- Diagnostic -- Périodiques
Imagerie médicale
Neuroimagerie
Neurologie
Système nerveux
Périodique électronique (Descripteur de forme)
Ressource Internet (Descripteur de forme)
616.804754 - Journal URLs:
- http://jon.sagepub.com/ ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1552-6569 ↗
http://www.ingentaconnect.com/content/bpl/jon ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jon.12453 ↗
- Languages:
- English
- ISSNs:
- 1051-2284
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5021.548000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4572.xml