Application of paper spray ionization for explosives analysis. (4th September 2017)
- Record Type:
- Journal Article
- Title:
- Application of paper spray ionization for explosives analysis. (4th September 2017)
- Main Title:
- Application of paper spray ionization for explosives analysis
- Authors:
- Tsai, Chia‐Wei
Tipple, Christopher A.
Yost, Richard A. - Abstract:
- Abstract : Rationale: A desired feature in the analysis of explosives is to decrease the time of the entire analysis procedure, including sampling. A recently utilized ambient ionization technique, paper spray ionization (PSI), provides the possibility of combining sampling and ionization. However, an interesting phenomenon that occurs in generating negatively charged ions pose some challenges in applying PSI to explosives analysis. The goal of this work is to investigate the possible solutions for generating explosives ions in negative mode PSI. Methods: The analysis of 2, 4, 6‐trinitrotoluene (TNT), pentaerythritol tetranitrate (PETN), octahydro‐1, 3, 5, 7‐tetranitro‐1, 3, 5, 7‐tetrazocine (HMX), and 1, 3, 5‐trinitroperhydro‐1, 3, 5‐triazine (RDX) was performed. Several solvent systems with different surface tensions and additives were compared to determine their effect on the ionization of explosives. The solvents tested include tert ‐butanol, isopropanol, methanol, and acetonitrile. The additives tested were carbon tetrachloride and ammonium nitrate. Results: Of the solvents tested, isopropanol yielded the best results. In addition, adding ammonium nitrate to the isopropanol enhanced the analyte signal. Experimentally determined limits of detection (LODs) as low as 0.06 ng for PETN, on paper, were observed with isopropanol and the addition of 0.4 mM ammonium nitrate as the spray solution. In addition, the explosive components of two plastic explosive samples, CompositionAbstract : Rationale: A desired feature in the analysis of explosives is to decrease the time of the entire analysis procedure, including sampling. A recently utilized ambient ionization technique, paper spray ionization (PSI), provides the possibility of combining sampling and ionization. However, an interesting phenomenon that occurs in generating negatively charged ions pose some challenges in applying PSI to explosives analysis. The goal of this work is to investigate the possible solutions for generating explosives ions in negative mode PSI. Methods: The analysis of 2, 4, 6‐trinitrotoluene (TNT), pentaerythritol tetranitrate (PETN), octahydro‐1, 3, 5, 7‐tetranitro‐1, 3, 5, 7‐tetrazocine (HMX), and 1, 3, 5‐trinitroperhydro‐1, 3, 5‐triazine (RDX) was performed. Several solvent systems with different surface tensions and additives were compared to determine their effect on the ionization of explosives. The solvents tested include tert ‐butanol, isopropanol, methanol, and acetonitrile. The additives tested were carbon tetrachloride and ammonium nitrate. Results: Of the solvents tested, isopropanol yielded the best results. In addition, adding ammonium nitrate to the isopropanol enhanced the analyte signal. Experimentally determined limits of detection (LODs) as low as 0.06 ng for PETN, on paper, were observed with isopropanol and the addition of 0.4 mM ammonium nitrate as the spray solution. In addition, the explosive components of two plastic explosive samples, Composition 4 and Semtex, were successfully analyzed via surface sampling when using the developed method. Conclusions: The analysis of explosives using PSI‐MS in negative ion mode was achieved. The addition of ammonium nitrate to isopropanol, in general, enhanced the analyte signal and yielded better ionization stability. Real‐world explosive samples were analyzed, which demonstrates one of the potential applications of PSI‐MS analysis. … (more)
- Is Part Of:
- Rapid communications in mass spectrometry. Volume 31:Number 19(2017)
- Journal:
- Rapid communications in mass spectrometry
- Issue:
- Volume 31:Number 19(2017)
- Issue Display:
- Volume 31, Issue 19 (2017)
- Year:
- 2017
- Volume:
- 31
- Issue:
- 19
- Issue Sort Value:
- 2017-0031-0019-0000
- Page Start:
- 1565
- Page End:
- 1572
- Publication Date:
- 2017-09-04
- Subjects:
- Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/rcm.7932 ↗
- Languages:
- English
- ISSNs:
- 0951-4198
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7254.440000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4566.xml