Development of an easily adaptable, high sensitivity source for inlet ionization. Issue 34 (15th August 2017)
- Record Type:
- Journal Article
- Title:
- Development of an easily adaptable, high sensitivity source for inlet ionization. Issue 34 (15th August 2017)
- Main Title:
- Development of an easily adaptable, high sensitivity source for inlet ionization
- Authors:
- Lu, I-Chung
Elia, Efstathios A.
Zhang, Wen-Jing
Pophristic, Milan
Inutan, Ellen D.
McEwen, Charles N.
Trimpin, Sarah - Abstract:
- Abstract : Unexpected ionization processes were recently discovered for use in mass spectrometry in which no added energy is required to convert condensed-phase molecules to gas-phase ions with ESI-like charge states by simply introducing the matrix/analyte sample into the sub-atmospheric pressure of the mass spectrometer. Abstract : An unexpected ionization process was recently discovered for use in mass spectrometry in which no added energy is required to convert condensed-phase molecules to ESI-like gas-phase ions. This process offers the opportunity to greatly simplify ionization and reduce energy requirements for use with portable mass spectrometers. Here we designed and constructed minimal ion sources specifically for the new ionization methods, and demonstrate conversion of compounds directly to gas-phase ions with high sensitivity using matrix-assisted ionization without a laser, voltage, or heat. A variety of inlets and sample supports were tested for sample introduction with this minimalistic source, include a contactless 'vacuum cleaner' approach for analyzing samples as well as laser ablation for high spatial resolution. The analysis is astonishingly simple and the mass spectra surprisingly free of background ions. Analytes tested range from small molecules ( e.g. drugs) to nonvolatile compounds ( e.g. proteins). These developments are potentially useful in a variety of vendor-independent applications, especially where simplicity, miniaturization, or automationAbstract : Unexpected ionization processes were recently discovered for use in mass spectrometry in which no added energy is required to convert condensed-phase molecules to gas-phase ions with ESI-like charge states by simply introducing the matrix/analyte sample into the sub-atmospheric pressure of the mass spectrometer. Abstract : An unexpected ionization process was recently discovered for use in mass spectrometry in which no added energy is required to convert condensed-phase molecules to ESI-like gas-phase ions. This process offers the opportunity to greatly simplify ionization and reduce energy requirements for use with portable mass spectrometers. Here we designed and constructed minimal ion sources specifically for the new ionization methods, and demonstrate conversion of compounds directly to gas-phase ions with high sensitivity using matrix-assisted ionization without a laser, voltage, or heat. A variety of inlets and sample supports were tested for sample introduction with this minimalistic source, include a contactless 'vacuum cleaner' approach for analyzing samples as well as laser ablation for high spatial resolution. The analysis is astonishingly simple and the mass spectra surprisingly free of background ions. Analytes tested range from small molecules ( e.g. drugs) to nonvolatile compounds ( e.g. proteins). These developments are potentially useful in a variety of vendor-independent applications, especially where simplicity, miniaturization, or automation are desirable attributes. … (more)
- Is Part Of:
- Analytical methods. Volume 9:Issue 34(2017)
- Journal:
- Analytical methods
- Issue:
- Volume 9:Issue 34(2017)
- Issue Display:
- Volume 9, Issue 34 (2017)
- Year:
- 2017
- Volume:
- 9
- Issue:
- 34
- Issue Sort Value:
- 2017-0009-0034-0000
- Page Start:
- 4971
- Page End:
- 4978
- Publication Date:
- 2017-08-15
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c7ay00995j ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4557.xml