Closure of Secundum Atrial Septal Defects With the AMPLATZER Septal Occluder: A Prospective, Multicenter, Post-Approval Study. (August 2017)
- Record Type:
- Journal Article
- Title:
- Closure of Secundum Atrial Septal Defects With the AMPLATZER Septal Occluder: A Prospective, Multicenter, Post-Approval Study. (August 2017)
- Main Title:
- Closure of Secundum Atrial Septal Defects With the AMPLATZER Septal Occluder
- Authors:
- Turner, Daniel R.
Owada, Carl Y.
Sang, Charlie J.
Khan, Muhammad
Lim, D. Scott - Abstract:
- Abstract : Background—: Prospective data on the medium-term safety and effectiveness of the AMPLATZER Septal Occluder in clinical practice are not available. The objective of this study was to prospectively evaluate the risk of hemodynamic compromise and obtain medium-term survival data on patients implanted with the AMPLATZER Septal Occluder for percutaneous closure of secundum atrial septal defects. Methods and Results—: Subjects were enrolled prospectively at 50 US sites and followed for 2 years. Between 2008 and 2012, atrial septal defect closure with the AMPLATZER Septal Occluder was attempted in 1000 patients (aged 0.3–83.6 years, mean 21±22 years). Procedural closure occurred in 97.9%, with 1-month and 2-year closure 98.5% and 97.9%, respectively. Hemodynamic compromise occurred in 6 subjects (0.65%), because of dysrhythmia in 2, device embolization in 1, and cardiac erosion in 3. The rate of cardiac erosion was 0.3% (average 83, range 12–171 days from implant). Conclusions—: Closure of atrial septal defect with the AMPLATZER Septal Occluder is safe and effective. The rate of hemodynamic compromise and cardiac erosion is rare. The risk factors for cardiac erosion after device closure are not yet clear. Clinical Trial Registration—: URL:http://www.clinicaltrials.gov . Unique identifier: NCT00650936.
- Is Part Of:
- Circulation. Volume 10:Number 8(2017)
- Journal:
- Circulation
- Issue:
- Volume 10:Number 8(2017)
- Issue Display:
- Volume 10, Issue 8 (2017)
- Year:
- 2017
- Volume:
- 10
- Issue:
- 8
- Issue Sort Value:
- 2017-0010-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-08
- Subjects:
- catheterization -- echocardiography -- heart -- heart septal defects -- risk factors
Cardiovascular system -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Treatment -- Periodicals
616.105 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=01337495-000000000-00000 ↗
http://circinterventions.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCINTERVENTIONS.116.004212 ↗
- Languages:
- English
- ISSNs:
- 1941-7640
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262560
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4555.xml