Effect of Aggressive Blood Pressure Control on the Recurrence of Atrial Fibrillation After Catheter Ablation: A Randomized, Open-Label Clinical Trial (SMAC-AF [Substrate Modification With Aggressive Blood Pressure Control]). Issue 19 (9th May 2017)
- Record Type:
- Journal Article
- Title:
- Effect of Aggressive Blood Pressure Control on the Recurrence of Atrial Fibrillation After Catheter Ablation: A Randomized, Open-Label Clinical Trial (SMAC-AF [Substrate Modification With Aggressive Blood Pressure Control]). Issue 19 (9th May 2017)
- Main Title:
- Effect of Aggressive Blood Pressure Control on the Recurrence of Atrial Fibrillation After Catheter Ablation
- Authors:
- Parkash, Ratika
Wells, George A.
Sapp, John L.
Healey, Jeffrey S.
Tardif, Jean-Claude
Greiss, Isabelle
Rivard, Lena
Roux, Jean-Francois
Gula, Lorne
Nault, Isabelle
Novak, Paul
Birnie, David
Ha, Andrew
Wilton, Stephen B.
Mangat, Iqwal
Gray, Christopher
Gardner, Martin
Tang, Anthony S.L. - Abstract:
- Abstract : Background: Radiofrequency catheter ablation for atrial fibrillation has become an important therapy for AF; however, recurrence rates remain high. We proposed to determine whether aggressive blood pressure (BP) lowering prevents recurrent atrial fibrillation (AF) after catheter ablation in patients with AF and a high symptom burden. Methods: We randomly assigned 184 patients with AF and a BP >130/80 mm Hg to aggressive BP (target <120/80 mm Hg) or standard BP (target <140/90 mm Hg) treatment before their scheduled AF catheter ablation. The primary outcome was symptomatic recurrence of AF/atrial tachycardia/atrial flutter lasting >30 seconds, determined 3 months beyond catheter ablation by a blinded end-point evaluation. Results: The median follow-up was 14 months. At 6 months, the mean systolic BP was 123.2±13.2 mm Hg in the aggressive BP treatment group versus 135.4±15.7 mm Hg ( P <0.001) in the standard treatment group. The primary outcome occurred in 106 patients, 54 (61.4%) in the aggressive BP treatment group compared with 52 (61.2%) in the standard treatment group (hazard ratio=0.94; 95% confidence interval, 0.65–1.38; P =0.763). In the prespecified subgroup analysis of the influence of age, patients ≥61 years of age had a lower primary outcome event rate with aggressive BP (hazard ratio=0.58; 95% confidence interval, 0.34–0.97; P =0.013). There was a higher rate of hypotension requiring medication adjustment in the aggressive BP group (26% versus 0%).Abstract : Background: Radiofrequency catheter ablation for atrial fibrillation has become an important therapy for AF; however, recurrence rates remain high. We proposed to determine whether aggressive blood pressure (BP) lowering prevents recurrent atrial fibrillation (AF) after catheter ablation in patients with AF and a high symptom burden. Methods: We randomly assigned 184 patients with AF and a BP >130/80 mm Hg to aggressive BP (target <120/80 mm Hg) or standard BP (target <140/90 mm Hg) treatment before their scheduled AF catheter ablation. The primary outcome was symptomatic recurrence of AF/atrial tachycardia/atrial flutter lasting >30 seconds, determined 3 months beyond catheter ablation by a blinded end-point evaluation. Results: The median follow-up was 14 months. At 6 months, the mean systolic BP was 123.2±13.2 mm Hg in the aggressive BP treatment group versus 135.4±15.7 mm Hg ( P <0.001) in the standard treatment group. The primary outcome occurred in 106 patients, 54 (61.4%) in the aggressive BP treatment group compared with 52 (61.2%) in the standard treatment group (hazard ratio=0.94; 95% confidence interval, 0.65–1.38; P =0.763). In the prespecified subgroup analysis of the influence of age, patients ≥61 years of age had a lower primary outcome event rate with aggressive BP (hazard ratio=0.58; 95% confidence interval, 0.34–0.97; P =0.013). There was a higher rate of hypotension requiring medication adjustment in the aggressive BP group (26% versus 0%). Conclusions: In this study, this duration of aggressive BP treatment did not reduce atrial arrhythmia recurrence after catheter ablation for AF but resulted in more hypotension. Clinical Trial Registration: URL:http://www.clinicaltrials.gov . Unique identifier: NCT00438113. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 135:Issue 19(2017)
- Journal:
- Circulation
- Issue:
- Volume 135:Issue 19(2017)
- Issue Display:
- Volume 135, Issue 19 (2017)
- Year:
- 2017
- Volume:
- 135
- Issue:
- 19
- Issue Sort Value:
- 2017-0135-0019-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-05-09
- Subjects:
- atrial fibrillation -- catheter ablation -- hypertension
Blood -- Circulation -- Periodicals
Cardiovascular system -- Periodicals
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
Blood Circulation
Cardiovascular System
Vascular Diseases
616.1 - Journal URLs:
- http://ovidsp.tx.ovid.com/sp-3.4.2a/ovidweb.cgi?&S=HFFJFPCLPODDKOLGNCALDCMCIACKAA00&Browse=Toc+Children%7cNO%7cS.sh.1384_1326796138_84.1384_1326796138_96.1384_1326796138_97%7c66%7c50 ↗
http://www.circulationaha.org ↗
http://circ.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCULATIONAHA.116.026230 ↗
- Languages:
- English
- ISSNs:
- 0009-7322
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4545.xml