Evaluation of a reproducible breath hold technique for the SABR treatment of lower lobe lung tumours. Issue 3 (7th March 2017)
- Record Type:
- Journal Article
- Title:
- Evaluation of a reproducible breath hold technique for the SABR treatment of lower lobe lung tumours. Issue 3 (7th March 2017)
- Main Title:
- Evaluation of a reproducible breath hold technique for the SABR treatment of lower lobe lung tumours
- Authors:
- Barrett, S.
Taylor, A.
Rock, L. - Abstract:
- Abstract: Aim: Deep inspiration breath hold (DIBH) is a method of motion management used in stereotactic ablative body radiotherapy (SABR) for lung tumours. An external gating block marker can be used as a tumour motion surrogate, however, inter-fraction gross target volume (GTV) displacement within DIBH occurs. This study measured this displacement during a reproducible breath hold regime. In addition, factors such as position of the gating block marker were analysed. Methods and materials: A total of 121 cone beam computed tomography scans (CBCTs) from 22 patients who received DIBH SABR were retrospectively evaluated and the magnitude of inter-fraction GTV displacement was calculated for each fraction. This data was analysed to assess if any correlation existed between tumour displacement and variation in the gating block marker position on the patient, the amplitude of breath hold (BH) at computed tomography (CT), the amplitude of BH at treatment and the tumour location. The measured tumour displacement was applied to the original planning CT to evaluate the dosimetric effect on surrounding organs at risk (OARs) using cumulative dose volume histograms (DVHs). Results: BH amplitude was reproducible within 0·13±0·1 cm (mean±standard deviation). The magnitude of tumour displacement within BH ranged from 0 to 1·52 cm (0·41±0·28 cm). Displacement in the superior-inferior, anterior-posterior and left-right planes were 0·31±0·26 cm, 0·16±0·18 cm and 0·07±0·12 cm, respectively.Abstract: Aim: Deep inspiration breath hold (DIBH) is a method of motion management used in stereotactic ablative body radiotherapy (SABR) for lung tumours. An external gating block marker can be used as a tumour motion surrogate, however, inter-fraction gross target volume (GTV) displacement within DIBH occurs. This study measured this displacement during a reproducible breath hold regime. In addition, factors such as position of the gating block marker were analysed. Methods and materials: A total of 121 cone beam computed tomography scans (CBCTs) from 22 patients who received DIBH SABR were retrospectively evaluated and the magnitude of inter-fraction GTV displacement was calculated for each fraction. This data was analysed to assess if any correlation existed between tumour displacement and variation in the gating block marker position on the patient, the amplitude of breath hold (BH) at computed tomography (CT), the amplitude of BH at treatment and the tumour location. The measured tumour displacement was applied to the original planning CT to evaluate the dosimetric effect on surrounding organs at risk (OARs) using cumulative dose volume histograms (DVHs). Results: BH amplitude was reproducible within 0·13±0·1 cm (mean±standard deviation). The magnitude of tumour displacement within BH ranged from 0 to 1·52 cm (0·41±0·28 cm). Displacement in the superior-inferior, anterior-posterior and left-right planes were 0·31±0·26 cm, 0·16±0·18 cm and 0·07±0·12 cm, respectively. No statistically significant correlation was detected between tumour displacement within DIBH and the factors investigated. The range of variation in OAR dose was −7·0 to +3·6 Gy with one statistically significant increase in OAR dose observed (oesophagus mean dose increasing by 0·16 Gy). Findings: Reproducible BH was achievable across a range of patients. Inter-fraction GTV displacement measured 0·41±0·28 cm. Due to this low level of motion, the correction of soft tissue moves did not adversely affect OAR dose. … (more)
- Is Part Of:
- Journal of radiotherapy in practice. Volume 16:Issue 3(2016)
- Journal:
- Journal of radiotherapy in practice
- Issue:
- Volume 16:Issue 3(2016)
- Issue Display:
- Volume 16, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 16
- Issue:
- 3
- Issue Sort Value:
- 2016-0016-0003-0000
- Page Start:
- 311
- Page End:
- 318
- Publication Date:
- 2017-03-07
- Subjects:
- deep inspiration breath hold, -- inter-fraction motion, -- lung, -- OAR tolerances, -- stereotactic
Radiotherapy -- Periodicals
615.842005 - Journal URLs:
- http://journals.cambridge.org/action/displayJournal?jid=JRP ↗
- DOI:
- 10.1017/S1460396917000097 ↗
- Languages:
- English
- ISSNs:
- 1460-3969
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 4540.xml