Visualizing Localized Reentry With Ultra–High Density Mapping in Iatrogenic Atrial Tachycardia: Beware Pseudo-Reentry. (April 2017)
- Record Type:
- Journal Article
- Title:
- Visualizing Localized Reentry With Ultra–High Density Mapping in Iatrogenic Atrial Tachycardia: Beware Pseudo-Reentry. (April 2017)
- Main Title:
- Visualizing Localized Reentry With Ultra–High Density Mapping in Iatrogenic Atrial Tachycardia
- Authors:
- Luther, Vishal
Sikkel, Markus
Bennett, Nathan
Guerrero, Fernando
Leong, Kevin
Qureshi, Norman
Ng, Fu Siong
Hayat, Sajad A.
Sohaib, S.M. Afzal
Malcolme-Lawes, Louisa
Lim, Elaine
Wright, Ian
Koa-Wing, Michael
Lefroy, David C.
Linton, Nick W.F.
Whinnett, Zachary
Kanagaratnam, Prapa
Davies, D. Wyn
Peters, Nicholas S.
Lim, Phang Boon - Abstract:
- Abstract : Background—: The activation pattern of localized reentry (LR) in atrial tachycardia remains incompletely understood. We used the ultra–high density Rhythmia mapping system to study activation patterns in LR. Methods and Results—: LR was suggested by small rotatory activations (carousels) containing the full spectrum of the color-coded map. Twenty-three left-sided atrial tachycardias were mapped in 15 patients (age: 64±11 years). 16 253±9192 points were displayed per map, collected over 26±14 minutes. A total of 50 carousels were identified (median 2; quartiles 1–3 per map), although this represented LR in only n=7 out of 50 (14%): here, rotation occurred around a small area of scar (<0.03 mV; 12±6 mm diameter). In LR, electrograms along the carousel encompassed the full tachycardia cycle length, and surrounding activation moved away from the carousel in all directions. Ablating fractionated electrograms (117±18 ms; 44±13% of tachycardia cycle length) within the carousel interrupted the tachycardia in every LR case. All remaining carousels were pseudo-reentrant (n=43/50 [86%]) occurring in areas of wavefront collision (n=21; median 0.5; quartiles 0–2 per map) or as artifact because of annotation of noise or interpolation in areas of incomplete mapping (n=22; median 1, quartiles 0–2 per map). Pseudo-reentrant carousels were incorrectly ablated in 5 cases having been misinterpreted as LR. Conclusions—: The activation pattern of LR is of small stable rotationalAbstract : Background—: The activation pattern of localized reentry (LR) in atrial tachycardia remains incompletely understood. We used the ultra–high density Rhythmia mapping system to study activation patterns in LR. Methods and Results—: LR was suggested by small rotatory activations (carousels) containing the full spectrum of the color-coded map. Twenty-three left-sided atrial tachycardias were mapped in 15 patients (age: 64±11 years). 16 253±9192 points were displayed per map, collected over 26±14 minutes. A total of 50 carousels were identified (median 2; quartiles 1–3 per map), although this represented LR in only n=7 out of 50 (14%): here, rotation occurred around a small area of scar (<0.03 mV; 12±6 mm diameter). In LR, electrograms along the carousel encompassed the full tachycardia cycle length, and surrounding activation moved away from the carousel in all directions. Ablating fractionated electrograms (117±18 ms; 44±13% of tachycardia cycle length) within the carousel interrupted the tachycardia in every LR case. All remaining carousels were pseudo-reentrant (n=43/50 [86%]) occurring in areas of wavefront collision (n=21; median 0.5; quartiles 0–2 per map) or as artifact because of annotation of noise or interpolation in areas of incomplete mapping (n=22; median 1, quartiles 0–2 per map). Pseudo-reentrant carousels were incorrectly ablated in 5 cases having been misinterpreted as LR. Conclusions—: The activation pattern of LR is of small stable rotational activations (carousels), and this drove 30% (7/23) of our postablation atrial tachycardias. However, this appearance is most often pseudo-reentrant and must be differentiated by interpretation of electrograms in the candidate circuit and activation in the wider surrounding region. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 10:Number 4(2017)
- Journal:
- Circulation
- Issue:
- Volume 10:Number 4(2017)
- Issue Display:
- Volume 10, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 10
- Issue:
- 4
- Issue Sort Value:
- 2017-0010-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-04
- Subjects:
- atrial fibrillation -- cardiac electrophysiology -- fibrosis -- tachycardia, supraventricular
Arrhythmia -- Periodicals
Heart -- Electric properties -- Periodicals
616.128 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01337493-000000000-00000 ↗
http://circep.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCEP.116.004724 ↗
- Languages:
- English
- ISSNs:
- 1941-3149
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4537.xml