Positron Emission Tomography and Single-Photon Emission Computed Tomography Imaging in the Diagnosis of Cardiac Implantable Electronic Device Infection: A Systematic Review and Meta-Analysis. (April 2017)
- Record Type:
- Journal Article
- Title:
- Positron Emission Tomography and Single-Photon Emission Computed Tomography Imaging in the Diagnosis of Cardiac Implantable Electronic Device Infection: A Systematic Review and Meta-Analysis. (April 2017)
- Main Title:
- Positron Emission Tomography and Single-Photon Emission Computed Tomography Imaging in the Diagnosis of Cardiac Implantable Electronic Device Infection
- Authors:
- Juneau, Daniel
Golfam, Mohammad
Hazra, Samir
Zuckier, Lionel S.
Garas, Shady
Redpath, Calum
Bernick, Jordan
Leung, Eugene
Chih, Sharon
Wells, George
Beanlands, Rob S.B.
Chow, Benjamin J.W. - Abstract:
- Abstract : Background—: The use of cardiac implantable electronic devices (CIED) is increasing, and their associated infections result in significant morbidity and mortality. The introduction of better cardiac imaging techniques could be useful for diagnosing this condition and guiding therapy. Our objective was to systematically assess the diagnostic accuracy of Fluor-18-fluorodeoxyglucose positron emission tomography and computed tomography, labeled leukocyte scintigraphy (LS), and Gallium-67 citrate scintigraphy for the diagnosis of CIED infection. Methods and Results—: A systematic review of the literature and meta-analysis on the use of all 3 modalities in CIED infection were conducted. Pooled sensitivity, specificity, and summary receiver operating characteristic curves of each imaging modalities were determined. The literature search identified 2493 articles. A total of 13 articles (11 studies for 18 F-FDG PET-CT and 2 for LS), met the inclusion criteria. No studies for 67 Ga citrate scintigraphy met the inclusion criteria. The pooled sensitivity of 18 F-FDG PET-CT for the diagnosis of CIED infection was 87% (95% CI, 82%–91%) and pooled specificity was 94% (95% CI, 88%–98%). The summary receiver operating characteristic curve analysis demonstrated good overall accuracy, with an area under the curve of 0.935. There were insufficient data to do a meta-analysis for LS, but both studies reported sensitivity above 90% and specificity of 100%. Conclusions—: Both 18 F-FDGAbstract : Background—: The use of cardiac implantable electronic devices (CIED) is increasing, and their associated infections result in significant morbidity and mortality. The introduction of better cardiac imaging techniques could be useful for diagnosing this condition and guiding therapy. Our objective was to systematically assess the diagnostic accuracy of Fluor-18-fluorodeoxyglucose positron emission tomography and computed tomography, labeled leukocyte scintigraphy (LS), and Gallium-67 citrate scintigraphy for the diagnosis of CIED infection. Methods and Results—: A systematic review of the literature and meta-analysis on the use of all 3 modalities in CIED infection were conducted. Pooled sensitivity, specificity, and summary receiver operating characteristic curves of each imaging modalities were determined. The literature search identified 2493 articles. A total of 13 articles (11 studies for 18 F-FDG PET-CT and 2 for LS), met the inclusion criteria. No studies for 67 Ga citrate scintigraphy met the inclusion criteria. The pooled sensitivity of 18 F-FDG PET-CT for the diagnosis of CIED infection was 87% (95% CI, 82%–91%) and pooled specificity was 94% (95% CI, 88%–98%). The summary receiver operating characteristic curve analysis demonstrated good overall accuracy, with an area under the curve of 0.935. There were insufficient data to do a meta-analysis for LS, but both studies reported sensitivity above 90% and specificity of 100%. Conclusions—: Both 18 F-FDG PET-CT and LS yield high sensitivity, specificity, and accuracy, and thus seem to be useful for the diagnosis of CIED infection, based on robust data for 18 F-FDG PET-CT but limited data for LS. When available, 18 F-FDG PET-CT may be preferred. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 10:Number 4(2017)
- Journal:
- Circulation
- Issue:
- Volume 10:Number 4(2017)
- Issue Display:
- Volume 10, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 10
- Issue:
- 4
- Issue Sort Value:
- 2017-0010-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-04
- Subjects:
- Fluor-18-fluorodeoxyglucose -- gallium -- leukocyte -- positron emission tomography
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.1075405 - Journal URLs:
- http://circimaging.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCIMAGING.116.005772 ↗
- Languages:
- English
- ISSNs:
- 1941-9651
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262750
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4527.xml