Correction of gradient nonlinearity artifacts in prospective motion correction for 7T MRI. Issue 4 (5th May 2014)
- Record Type:
- Journal Article
- Title:
- Correction of gradient nonlinearity artifacts in prospective motion correction for 7T MRI. Issue 4 (5th May 2014)
- Main Title:
- Correction of gradient nonlinearity artifacts in prospective motion correction for 7T MRI
- Authors:
- Yarach, Uten
Luengviriya, Chaiya
Danishad, Appu
Stucht, Daniel
Godenschweger, Frank
Schulze, Peter
Speck, Oliver - Abstract:
- Abstract : Purpose: To demonstrate the effect of gradient nonlinearity and develop a method for correction of gradient nonlinearity artifacts in prospective motion correction (Mo‐Co). Methods: Nonlinear gradients can induce geometric distortions in magnetic resonance imaging, leading to pixel shifts with errors of up to several millimeters, thereby interfering with precise localization of anatomical structures. Prospective Mo‐Co has been extended by conventional gradient warp correction applied to individual phase encoding steps/groups during the reconstruction. The gradient‐related displacements are approximated using spherical harmonic functions. In addition, the combination of this method with a retrospective correction of the changes in the coil sensitivity profiles relative to the object (augmented sensitivity encoding (SENSE) reconstruction) was evaluated in simulation and experimental data. Results: Prospective Mo‐Co under gradient fields and coils sensitivity inconsistencies results in residual blurring, spatial distortion, and coil sensitivity mismatch artifacts. These errors can be considerably mitigated by the proposed method. High image quality with very little remaining artifacts was achieved after a few iterations. The relative image errors decreased from 25.7% to below 17.3% after 10 iterations. Conclusion: The combined correction of gradient nonlinearity and sensitivity map variation leads to a pronounced reduction of residual motion artifacts inAbstract : Purpose: To demonstrate the effect of gradient nonlinearity and develop a method for correction of gradient nonlinearity artifacts in prospective motion correction (Mo‐Co). Methods: Nonlinear gradients can induce geometric distortions in magnetic resonance imaging, leading to pixel shifts with errors of up to several millimeters, thereby interfering with precise localization of anatomical structures. Prospective Mo‐Co has been extended by conventional gradient warp correction applied to individual phase encoding steps/groups during the reconstruction. The gradient‐related displacements are approximated using spherical harmonic functions. In addition, the combination of this method with a retrospective correction of the changes in the coil sensitivity profiles relative to the object (augmented sensitivity encoding (SENSE) reconstruction) was evaluated in simulation and experimental data. Results: Prospective Mo‐Co under gradient fields and coils sensitivity inconsistencies results in residual blurring, spatial distortion, and coil sensitivity mismatch artifacts. These errors can be considerably mitigated by the proposed method. High image quality with very little remaining artifacts was achieved after a few iterations. The relative image errors decreased from 25.7% to below 17.3% after 10 iterations. Conclusion: The combined correction of gradient nonlinearity and sensitivity map variation leads to a pronounced reduction of residual motion artifacts in prospectively motion‐corrected data.Magn Reson Med 73:1562–1569, 2015. © 2014 Wiley Periodicals, Inc. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 73:Issue 4(2015:Apr.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 73:Issue 4(2015:Apr.)
- Issue Display:
- Volume 73, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 73
- Issue:
- 4
- Issue Sort Value:
- 2015-0073-0004-0000
- Page Start:
- 1562
- Page End:
- 1569
- Publication Date:
- 2014-05-05
- Subjects:
- prospective motion correction -- gradient nonlinearity -- gradient warp correction -- coil sensitivity mismatch
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25283 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4510.xml