Constrained image‐based B0 shimming accounting for "local minimum traps" in the optimization and field inhomogeneities outside the region of interest. Issue 4 (8th April 2014)
- Record Type:
- Journal Article
- Title:
- Constrained image‐based B0 shimming accounting for "local minimum traps" in the optimization and field inhomogeneities outside the region of interest. Issue 4 (8th April 2014)
- Main Title:
- Constrained image‐based B0 shimming accounting for "local minimum traps" in the optimization and field inhomogeneities outside the region of interest
- Authors:
- Fillmer, Ariane
Kirchner, Thomas
Cameron, Donnie
Henning, Anke - Abstract:
- Abstract : Purpose: To improve B 0 shimming for applications in high‐ and ultrahigh‐field magnetic resonance imaging and magnetic resonance spectroscopy. Methods: An existing image‐based constrained B 0 shimming algorithm was enhanced using two techniques: (1) A region of less interest was introduced to control B 0 field inhomogeneities in the vicinity of the region of interest; (2) multiple sets of starting values were used for the fitting routine, to avoid "getting trapped" in a local minimum of the optimization function. The influence of constraints during the fitting procedure, due to hardware limitations, on the B 0 shim result was investigated. The performance of this algorithm was compared to other B 0 shim algorithms for typical shim problems in head and body applications at 3T and 7T. Results: Utilization of a weighted region of less interest lead to a significant gain in B 0 homogeneity adjacent to the region of interest. The loss of B 0 quality due to the enlarged total shim volume within the region of interest remained minimal, allowing for improved artifact reduction in magnetic resonance spectroscopic imaging. Multiple sets of starting values and consideration of shim field constraints led to an additional gain in B 0 shim quality. Conclusion: The proposed algorithm allows for more flexible control of B 0 inhomogeneities and, hence, enables gains in image and spectral quality for MR applications.Magn Reson Med 73:1370–1380, 2015. © 2014 Wiley Periodicals, Inc.
- Is Part Of:
- Magnetic resonance in medicine. Volume 73:Issue 4(2015:Apr.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 73:Issue 4(2015:Apr.)
- Issue Display:
- Volume 73, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 73
- Issue:
- 4
- Issue Sort Value:
- 2015-0073-0004-0000
- Page Start:
- 1370
- Page End:
- 1380
- Publication Date:
- 2014-04-08
- Subjects:
- B0 shimming -- image‐based B0 shimming -- projection‐based B0 shimming -- shim term interactions -- region of less interest -- constrained fitting -- magnetic resonance spectroscopic imaging
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25248 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4510.xml