Design, methodology, and baseline data of the Personalized Addition Lenses Clinical Trial (PACT). Issue 11 (March 2017)
- Record Type:
- Journal Article
- Title:
- Design, methodology, and baseline data of the Personalized Addition Lenses Clinical Trial (PACT). Issue 11 (March 2017)
- Main Title:
- Design, methodology, and baseline data of the Personalized Addition Lenses Clinical Trial (PACT)
- Authors:
- Yu, Xinping
Zhang, Binjun
Bao, Jinhua
Zhang, Junxiao
Wu, Ge
Xu, Jinling
Zheng, Jingwei
Drobe, Björn
Chen, Hao - Other Names:
- Villani. Edoardo section editor.
- Abstract:
- Abstract: Background: The aim of this study was to describe the design, methods, and baseline characteristics of children enrolled in the Personalized Addition lenses Clinical Trial (PACT). PACT aims to test the myopia control efficacy of progressive addition lenses (PALs) with personalized addition values compared with standard (+2.00 D) addition PALs and single vision lenses (SVLs). Methods: PACT is a randomized, controlled, double-masked clinical trial. Two hundred eleven myopic Chinese children (7–12 years) were enrolled and randomized into 1 of the 3 following groups: personalized addition PALs; +2.00 addition PALs; and SVLs. Personalized addition values were determined based on the highest addition that satisfied Sheard criterion. Axial length and other biometric data were also recorded. Results: At baseline, no differences were found between the right and left eyes for any of the main parameters. The enrolled children were 9.7 ± 1.1 years' old with cycloplegic autorefraction (right eye [OD]: −2.36 ± 0.64 D), near phoria (1.0 ± 5.0 prism diopter esophoria), lag of accommodation (1.40 ± 0.50 D) and axial length (OD: 24.58 ± 0.74 mm). The personalized addition values ranged from +0.75 to +3.00 (average ± SD: 2.19 ± 0.73 D). Conclusion: PACT is a clinical trial evaluating whether myopia progression in children can be slowed by wearing personalized addition PALs compared with fixed addition PALs and SVLs as measured by cycloplegic autorefraction and axial length. BaselineAbstract: Background: The aim of this study was to describe the design, methods, and baseline characteristics of children enrolled in the Personalized Addition lenses Clinical Trial (PACT). PACT aims to test the myopia control efficacy of progressive addition lenses (PALs) with personalized addition values compared with standard (+2.00 D) addition PALs and single vision lenses (SVLs). Methods: PACT is a randomized, controlled, double-masked clinical trial. Two hundred eleven myopic Chinese children (7–12 years) were enrolled and randomized into 1 of the 3 following groups: personalized addition PALs; +2.00 addition PALs; and SVLs. Personalized addition values were determined based on the highest addition that satisfied Sheard criterion. Axial length and other biometric data were also recorded. Results: At baseline, no differences were found between the right and left eyes for any of the main parameters. The enrolled children were 9.7 ± 1.1 years' old with cycloplegic autorefraction (right eye [OD]: −2.36 ± 0.64 D), near phoria (1.0 ± 5.0 prism diopter esophoria), lag of accommodation (1.40 ± 0.50 D) and axial length (OD: 24.58 ± 0.74 mm). The personalized addition values ranged from +0.75 to +3.00 (average ± SD: 2.19 ± 0.73 D). Conclusion: PACT is a clinical trial evaluating whether myopia progression in children can be slowed by wearing personalized addition PALs compared with fixed addition PALs and SVLs as measured by cycloplegic autorefraction and axial length. Baseline data were comparable with those of previous myopia control studies in children. Subjects will be followed up every 6 months for 2 years. Abstract : Supplemental Digital Content is available in the text … (more)
- Is Part Of:
- Medicine. Volume 96:Issue 11(2017)
- Journal:
- Medicine
- Issue:
- Volume 96:Issue 11(2017)
- Issue Display:
- Volume 96, Issue 11 (2017)
- Year:
- 2017
- Volume:
- 96
- Issue:
- 11
- Issue Sort Value:
- 2017-0096-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-03
- Subjects:
- myopic children -- phoria -- progressive addition lenses
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000006069 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4505.xml