Exponential Decay Metrics of Topical Tetracaine Hydrochloride Administration Describe Corneal Anesthesia Properties Mechanistically. Issue 3 (March 2017)
- Record Type:
- Journal Article
- Title:
- Exponential Decay Metrics of Topical Tetracaine Hydrochloride Administration Describe Corneal Anesthesia Properties Mechanistically. Issue 3 (March 2017)
- Main Title:
- Exponential Decay Metrics of Topical Tetracaine Hydrochloride Administration Describe Corneal Anesthesia Properties Mechanistically
- Authors:
- Ethington, Jason
Goldmeier, David
Gaynes, Bruce I. - Abstract:
- Abstract : Purpose: To identify pharmacodynamic (PD) and pharmacokinetic (PK) metrics that aid in mechanistic understanding of dosage considerations for prolonged corneal anesthesia. Methods: A rabbit model using 0.5% tetracaine hydrochloride was used to induce corneal anesthesia in conjunction with Cochet–Bonnet anesthesiometry. Metrics were derived describing PD-PK parameters of the time-dependent domain of recovery in corneal sensitivity. Curve fitting used a 1-phase exponential dissociation paradigm assuming a 1-compartment PK model. Derivation of metrics including half-life and mean ligand residence time, tau (τ), was predicted by nonlinear regression. Bioavailability was determined by area under the curve of the dose–response relationship with varying drop volumes. Results: Maximal corneal anesthesia maintained a plateau with a recovery inflection at the approximate time of predicted corneal drug half-life. PDs of recovery of corneal anesthesia were consistent with a first-order drug elimination rate. The mean ligand residence time (tau, τ) was 41.7 minutes, and half-life was 28.89 minutes. The mean estimated corneal elimination rate constant (ke ) was 0.02402 minute −1 . Duration of corneal anesthesia ranged from 55 to 58 minutes. There was no difference in time domain PD area under the curve between drop volumes. Conclusions: Use of a small drop volume of a topical anesthetic (as low as 11 μL) is bioequivalent to conventional drop size and seems to optimize dosingAbstract : Purpose: To identify pharmacodynamic (PD) and pharmacokinetic (PK) metrics that aid in mechanistic understanding of dosage considerations for prolonged corneal anesthesia. Methods: A rabbit model using 0.5% tetracaine hydrochloride was used to induce corneal anesthesia in conjunction with Cochet–Bonnet anesthesiometry. Metrics were derived describing PD-PK parameters of the time-dependent domain of recovery in corneal sensitivity. Curve fitting used a 1-phase exponential dissociation paradigm assuming a 1-compartment PK model. Derivation of metrics including half-life and mean ligand residence time, tau (τ), was predicted by nonlinear regression. Bioavailability was determined by area under the curve of the dose–response relationship with varying drop volumes. Results: Maximal corneal anesthesia maintained a plateau with a recovery inflection at the approximate time of predicted corneal drug half-life. PDs of recovery of corneal anesthesia were consistent with a first-order drug elimination rate. The mean ligand residence time (tau, τ) was 41.7 minutes, and half-life was 28.89 minutes. The mean estimated corneal elimination rate constant (ke ) was 0.02402 minute −1 . Duration of corneal anesthesia ranged from 55 to 58 minutes. There was no difference in time domain PD area under the curve between drop volumes. Conclusions: Use of a small drop volume of a topical anesthetic (as low as 11 μL) is bioequivalent to conventional drop size and seems to optimize dosing regiments with a little effect on ke . Prolongation of corneal anesthesia may therefore be best achieved with administration of small drop volumes at time intervals corresponding to the half-life of drug decay from the corneal compartment. … (more)
- Is Part Of:
- Cornea. Volume 36:Issue 3(2017)
- Journal:
- Cornea
- Issue:
- Volume 36:Issue 3(2017)
- Issue Display:
- Volume 36, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 36
- Issue:
- 3
- Issue Sort Value:
- 2017-0036-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-03
- Subjects:
- anesthetic -- model -- cornea -- dose
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000001125 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4499.xml