Clinical evaluation of a block sequential regularized expectation maximization reconstruction algorithm in 18F-FDG PET/CT studies. Issue 1 (January 2017)
- Record Type:
- Journal Article
- Title:
- Clinical evaluation of a block sequential regularized expectation maximization reconstruction algorithm in 18F-FDG PET/CT studies. Issue 1 (January 2017)
- Main Title:
- Clinical evaluation of a block sequential regularized expectation maximization reconstruction algorithm in 18F-FDG PET/CT studies
- Authors:
- Sah, Bert-Ram
Stolzmann, Paul
Delso, Gaspar
Wollenweber, Scott D.
Hüllner, Martin
Hakami, Yahya A.
Queiroz, Marcelo A.
Barbosa, Felipe de Galiza
von Schulthess, Gustav K.
Pietsch, Carsten
Veit-Haibach, Patrick - Abstract:
- Abstract : Purpose: To investigate the clinical performance of a block sequential regularized expectation maximization (BSREM) penalized likelihood reconstruction algorithm in oncologic PET/computed tomography (CT) studies. Methods: A total of 410 reconstructions of 41 fluorine-18 fluorodeoxyglucose-PET/CT studies of 41 patients with a total of 2010 lesions were analyzed by two experienced nuclear medicine physicians. Images were reconstructed with BSREM (with four different β values) or ordered subset expectation maximization (OSEM) algorithm with/without time-of-flight (TOF/non-TOF) corrections. OSEM reconstruction postfiltering was 4.0 mm full-width at half-maximum; BSREM did not use postfiltering. Evaluation of general image quality was performed with a five-point scale using maximum intensity projections. Artifacts (category 1), image sharpness (category 2), noise (category 3), and lesion detectability (category 4) were analyzed using a four-point scale. Size and maximum standardized uptake value (SUVmax ) of lesions were measured by a third reader not involved in the image evaluation. Results: BSREM-TOF reconstructions showed the best results in all categories, independent of different body compartments. In all categories, BSREM non-TOF reconstructions were significantly better than OSEM non-TOF reconstructions ( P <0.001). In almost all categories, BSREM non-TOF reconstruction was comparable to or better than the OSEM-TOF algorithm ( P <0.001 for general imageAbstract : Purpose: To investigate the clinical performance of a block sequential regularized expectation maximization (BSREM) penalized likelihood reconstruction algorithm in oncologic PET/computed tomography (CT) studies. Methods: A total of 410 reconstructions of 41 fluorine-18 fluorodeoxyglucose-PET/CT studies of 41 patients with a total of 2010 lesions were analyzed by two experienced nuclear medicine physicians. Images were reconstructed with BSREM (with four different β values) or ordered subset expectation maximization (OSEM) algorithm with/without time-of-flight (TOF/non-TOF) corrections. OSEM reconstruction postfiltering was 4.0 mm full-width at half-maximum; BSREM did not use postfiltering. Evaluation of general image quality was performed with a five-point scale using maximum intensity projections. Artifacts (category 1), image sharpness (category 2), noise (category 3), and lesion detectability (category 4) were analyzed using a four-point scale. Size and maximum standardized uptake value (SUVmax ) of lesions were measured by a third reader not involved in the image evaluation. Results: BSREM-TOF reconstructions showed the best results in all categories, independent of different body compartments. In all categories, BSREM non-TOF reconstructions were significantly better than OSEM non-TOF reconstructions ( P <0.001). In almost all categories, BSREM non-TOF reconstruction was comparable to or better than the OSEM-TOF algorithm ( P <0.001 for general image quality, image sharpness, noise, and P =1.0 for artifact). Only in lesion detectability was OSEM-TOF significantly better than BSREM non-TOF ( P <0.001). Both BSREM-TOF and BSREM non-TOF showed a decreasing SUVmax with increasing β values ( P <0.001) and TOF reconstructions showed a significantly higher SUVmax than non-TOF reconstructions ( P <0.001). Conclusion: The BSREM reconstruction algorithm showed a relevant improvement compared with OSEM reconstruction in PET/CT studies in all evaluated categories. BSREM might be used in clinical routine in conjunction with TOF to achieve better/higher image quality and lesion detectability or in PET/CT-systems without TOF-capability for enhancement of overall image quality as well. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Nuclear medicine communications. Volume 38:Issue 1(2017:Jan.)
- Journal:
- Nuclear medicine communications
- Issue:
- Volume 38:Issue 1(2017:Jan.)
- Issue Display:
- Volume 38, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 38
- Issue:
- 1
- Issue Sort Value:
- 2017-0038-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-01
- Subjects:
- image reconstruction -- penalized likelihood -- PET -- reconstruction algorithm
Nuclear medicine -- Periodicals
616.07575 - Journal URLs:
- http://journals.lww.com/nuclearmedicinecomm/pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗
http://www.lww.com/Product/0143-3636 ↗ - DOI:
- 10.1097/MNM.0000000000000604 ↗
- Languages:
- English
- ISSNs:
- 0143-3636
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6180.923000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4489.xml