A polydiacetylene-based colorimetric chemosensor for malondialdehyde detection: a food spoilage indicator. Issue 33 (11th August 2017)
- Record Type:
- Journal Article
- Title:
- A polydiacetylene-based colorimetric chemosensor for malondialdehyde detection: a food spoilage indicator. Issue 33 (11th August 2017)
- Main Title:
- A polydiacetylene-based colorimetric chemosensor for malondialdehyde detection: a food spoilage indicator
- Authors:
- Kim, Sangwan
Lee, Sunjong
Ahn, Yejin
Kim, Hyun Ki
Koh, Joonseok
Kim, Sung Dong
Kim, Bong-Gi - Abstract:
- Abstract : A polydiacetylene-based colorimetric sensor was devised to detect malondialdehyde as a food spoilage indicator. Abstract : A colorimetric chemosensor adopting polydiacetylene derivatives was rationally designed to detect malondialdehyde (MDA) as a potential food spoilage indicator. A newly developed diacetylene monomer containing an active methylene group effectively reacted with the aldehyde units of the MDA molecule via Knoevenagel-type condensation and resulted in a CC bond, judging from the results of FT-IR spectroscopy. When the monomer was incorporated into polydiacetylene liposomes, they exhibited a strong change in color from blue to red in the presence of MDA molecules, even though their sensitivity was partly affected by the feed ratio of the applied diacetylene monomers during liposome preparation. In addition, it was verified that the devised MDA chemosensor selectively responded to the divalent MDA, rather than the monovalent butanal. The detection limit of the optimized MDA chemosensor was about 250 μM in solution, but when a film-type MDA chemosensor was fabricated through the accumulation of the liposomes on top of a nylon membrane and then applied, the detection limit improved dramatically, reaching down to 10 μM at room temperature, even by judging the change in color with the naked eye. To confirm that the change of the resulting Hue angle can reflect the detection sensitivity of the MDA chemosensor under different experimental conditions,Abstract : A polydiacetylene-based colorimetric sensor was devised to detect malondialdehyde as a food spoilage indicator. Abstract : A colorimetric chemosensor adopting polydiacetylene derivatives was rationally designed to detect malondialdehyde (MDA) as a potential food spoilage indicator. A newly developed diacetylene monomer containing an active methylene group effectively reacted with the aldehyde units of the MDA molecule via Knoevenagel-type condensation and resulted in a CC bond, judging from the results of FT-IR spectroscopy. When the monomer was incorporated into polydiacetylene liposomes, they exhibited a strong change in color from blue to red in the presence of MDA molecules, even though their sensitivity was partly affected by the feed ratio of the applied diacetylene monomers during liposome preparation. In addition, it was verified that the devised MDA chemosensor selectively responded to the divalent MDA, rather than the monovalent butanal. The detection limit of the optimized MDA chemosensor was about 250 μM in solution, but when a film-type MDA chemosensor was fabricated through the accumulation of the liposomes on top of a nylon membrane and then applied, the detection limit improved dramatically, reaching down to 10 μM at room temperature, even by judging the change in color with the naked eye. To confirm that the change of the resulting Hue angle can reflect the detection sensitivity of the MDA chemosensor under different experimental conditions, CIELAB analysis was conducted with the film-type MDA sensor. The results indicated that the Hue angle changed according to the MDA concentration, and the resulting slope can be quantitatively correlated with the sensitivity of the colorimetric detection system. … (more)
- Is Part Of:
- Journal of materials chemistry. Volume 5:Issue 33(2017)
- Journal:
- Journal of materials chemistry
- Issue:
- Volume 5:Issue 33(2017)
- Issue Display:
- Volume 5, Issue 33 (2017)
- Year:
- 2017
- Volume:
- 5
- Issue:
- 33
- Issue Sort Value:
- 2017-0005-0033-0000
- Page Start:
- 8553
- Page End:
- 8558
- Publication Date:
- 2017-08-11
- Subjects:
- Materials -- Periodicals
Chemistry, Analytic -- Periodicals
Optical materials -- Research -- Periodicals
Electronics -- Materials -- Research -- Periodicals
543.0284 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/tc# ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c7tc02311a ↗
- Languages:
- English
- ISSNs:
- 2050-7526
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5012.205300
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4471.xml